Evaluation of Active Protection Systems for Fire Extinguisher at Locomotive Depot

Abstract Introduction: A fire is an accident that can occur in the railroad industry. Locomotive depots have various work processes and fuels that can cause medium-II fires. An active protection system using fire extinguishers is one of the preventive efforts that can be performed along with evaluation. However, fire extinguisher evaluations based on the regulatory standard have never been performed in the Locomotive Depot of Daop 9. This study aimed to evaluate the suitability of a Fire Extinguisher at PT KAI Daop 9 Jember Locomotive Depot with Permenakertrans No. 4 of 1980.Methods: This study was an evaluation research. Data collection was conducted through semi-structured interviews to the Locomotive Depot Facility Supervisor, observations using a checklist sheet, and measurements. Data were analyzed using the univariate method and are presented using tables and narratives.Results: The Locomotive Depot had several hazards from welding, locomotive electrical systems, fuel, and cigarette butts. A fire prevention program consists of providing a fire protection system, training, reporting, and forming an emergency response team. The locomotive depot had 13 powder fire extinguishers weighing 3.5-12 kg. The suitability of fire extinguisher installation and maintenance is sufficient category with 66.7% for installation and 74.3% for maintenance.Conclusion: The Daop 9 Jember Locomotive Depot has several fire hazard risks and prevention programs. The suitability of the installation and maintenance of fire extinguishers was in a sufficient category. It is necessary to optimize fire prevention programmes through the cooperation of various parties to enforce applicable regulations.

Authors

Institutions

Publication Details

Journal
Journal of Public Health for Tropical and Coastal Region
Published
2024-12-30
DOI
https://doi.org/10.14710/jphtcr.v7i3.24834
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Active Protection Systems for Fire Extinguisher at Locomotive Depot

Ana Islamiyah Syamila, M. Irfan Fahmi, Kholfana Bintan Maula Aditya Putri, Evelyne Martha Limanda et al.
Journal of Public Health for Tropical and Coastal Region
Fire Detection and Safety Systems
article

Evaluation of Active Protection Systems for Fire Extinguisher at Locomotive Depot

Ana Islamiyah Syamila, M. Irfan Fahmi, Kholfana Bintan Maula Aditya Putri, Evelyne Martha Limanda, Yoka Bismayuda Prana
article en

Abstract

Abstract Introduction: A fire is an accident that can occur in the railroad industry. Locomotive depots have various work processes and fuels that can cause medium-II fires. An active protection system using fire extinguishers is one of the preventive efforts that can be performed along with evaluation. However, fire extinguisher evaluations based on the regulatory standard have never been performed in the Locomotive Depot of Daop 9. This study aimed to evaluate the suitability of a Fire Extinguisher at PT KAI Daop 9 Jember Locomotive Depot with Permenakertrans No. 4 of 1980.Methods: This study was an evaluation research. Data collection was conducted through semi-structured interviews to the Locomotive Depot Facility Supervisor, observations using a checklist sheet, and measurements. Data were analyzed using the univariate method and are presented using tables and narratives.Results: The Locomotive Depot had several hazards from welding, locomotive electrical systems, fuel, and cigarette butts. A fire prevention program consists of providing a fire protection system, training, reporting, and forming an emergency response team. The locomotive depot had 13 powder fire extinguishers weighing 3.5-12 kg. The suitability of fire extinguisher installation and maintenance is sufficient category with 66.7% for installation and 74.3% for maintenance.Conclusion: The Daop 9 Jember Locomotive Depot has several fire hazard risks and prevention programs. The suitability of the installation and maintenance of fire extinguishers was in a sufficient category. It is necessary to optimize fire prevention programmes through the cooperation of various parties to enforce applicable regulations.

Journal of Public Health for Tropical and Coastal RegionVol. 7(3)
Universitas Jember (ID)
Openalex Percentile: Top 70%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Active Protection Systems for Fire Extinguisher at Locomotive Depot — Ana Islamiyah Syamila, M. Irfan Fahmi, et al. · Journal of Public Health for Tropical and Coastal Region (2024) | TGRS Research Map | TGRS