Calculation and experimental verification of equivalent distributed circuit model based on refined iron core modelling

Abstract This research introduces an equivalent circuit model and a computational method to address complex mechanical motion issues through electromechanical analogies. The study initially refines core vibration characteristics using single‐ and multi‐degree‐of‐freedom models, subsequently establishing equivalent circuit models for these various degrees of freedom. However, employing high degree‐of‐freedom models for detailed modelling of the core proves overly cumbersome. The research advocates for a distributed equivalent circuit model to more accurately represent the core's layered structure, thus facilitating enhanced core modelling. Moreover, the study formulates a mechanical wave transmission equation pertinent to the vibration of the iron core, which constitutes the foundation of the distributed mechanical vibration model. This model comprehensively assesses the impact of three critical factors on core vibration: the non‐linearity of winding resistance, the electromechanical coupling coefficient, and the dynamic stiffness of the core. A case study elucidates the distinct influences of each factor on vibration characteristics. Furthermore, this study derives vibration calculations from a 60‐day overload ageing test conducted on a 10 kV transformer under 135°C overload conditions. The methodology involves integrating measured compression force values and the calculated dynamic stiffness of the core into an equivalent circuit model. Subsequent analysis compares the results from the equivalent circuit model with experimental measurements. These comparisons indicate an agreement between the calculated and measured values in the time–frequency domain, thereby confirming the accuracy of the equivalent circuit model calculations.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2024-12-30
DOI
https://doi.org/10.1049/hve2.12501
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation and experimental verification of equivalent distributed circuit model based on refined iron core modelling

Guanyu Chen, Tao Zhao, Lu Sun, Feng Xu et al.
High Voltage
Power Transformer Diagnostics and Insulation
article

Calculation and experimental verification of equivalent distributed circuit model based on refined iron core modelling

Guanyu Chen, Tao Zhao, Lu Sun, Feng Xu, Jiayi Guo, Yunpeng Liu, Hongliang Liu
article en

Abstract

Abstract This research introduces an equivalent circuit model and a computational method to address complex mechanical motion issues through electromechanical analogies. The study initially refines core vibration characteristics using single‐ and multi‐degree‐of‐freedom models, subsequently establishing equivalent circuit models for these various degrees of freedom. However, employing high degree‐of‐freedom models for detailed modelling of the core proves overly cumbersome. The research advocates for a distributed equivalent circuit model to more accurately represent the core's layered structure, thus facilitating enhanced core modelling. Moreover, the study formulates a mechanical wave transmission equation pertinent to the vibration of the iron core, which constitutes the foundation of the distributed mechanical vibration model. This model comprehensively assesses the impact of three critical factors on core vibration: the non‐linearity of winding resistance, the electromechanical coupling coefficient, and the dynamic stiffness of the core. A case study elucidates the distinct influences of each factor on vibration characteristics. Furthermore, this study derives vibration calculations from a 60‐day overload ageing test conducted on a 10 kV transformer under 135°C overload conditions. The methodology involves integrating measured compression force values and the calculated dynamic stiffness of the core into an equivalent circuit model. Subsequent analysis compares the results from the equivalent circuit model with experimental measurements. These comparisons indicate an agreement between the calculated and measured values in the time–frequency domain, thereby confirming the accuracy of the equivalent circuit model calculations.

High VoltageVol. 10(4)
North China Electric Power University (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
Peace, Justice and strong institutions
Openalex Percentile: Top 77%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.