An investigation into the thermal and hygric performance of bio-based wall systems

Renewable bio-based materials are emerging technologies within the construction industry, providing inventive solutions for reducing material waste and the carbon footprint of an inherently carbon-intensive sector. Previously they have been commonly investigated in isolation and there are a significant lack of case studies demonstrating the performance of bio-based materials in entire external wall designs. This study evaluates the thermal and hygric performance of five novel bio-based external wall systems, featuring highly innovative combinations of insulation, structural and façade materials. Large scale wall panels were designed, constructed and tested within a bespoke Large Environmental Chamber (LEC) to determine thermal performance and hygric behaviour using the heat flow method. Hygrothermal simulations with WUFI® Pro were conducted to assess condensation and mould risks. Insulation materials used were wood fibre, mycelium, sheep's wool and blown-in cellulose. Structural options were timber, Cross Laminated Timber (CLT) and also light-gauge steel, while facades were bio-based-polymeric composite material or bio-based treated timber cladding. Thermal transmittance and conductance were calculated along with time series analysis of temperature and relative humidity . The U-values of the five walls ranged from 0.13 W/m 2 K to 0.22 W/m 2 K and modelling simulations were in broad agreement with the practical results, with four of the five walls fulfilling an 0.18 W/m 2 K benchmark value based upon building regulations. The significance of the study is in the demonstration of the feasibility of a range of bio-based external wall designs, combining emerging material technologies, innovative design and building physics to contribute to the development of bio-based construction. • Bio-based materials are emerging in buildings to provide external wall systems. • 5 innovative bio-based external wall designs are tested for hygrothermal properties. • Insulation materials used are sheep's wool, cellulose, wood fibre and mycelium. • U-values of the bio-based walls are in the range of 0.13 W/m 2 K to 0.22 W/m 2 K. • Two designs have been constructed as living laboratory buildings.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-12-31
DOI
https://doi.org/10.1016/j.jobe.2024.111727
Citations
6
Primary Topic
Plant and Biological Electrophysiology Studies
Type
article
Field-Weighted Citation Impact
3.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An investigation into the thermal and hygric performance of bio-based wall systems

Stephen Emmitt, Daniel Maskell, Valeria Cascione, Barrie Dams et al.
6 citations
Journal of Building Engineering
Plant and Biological Electrophysiology Studies
3.60
article

An investigation into the thermal and hygric performance of bio-based wall systems

Stephen Emmitt, Daniel Maskell, Valeria Cascione, Barrie Dams, Andrew Shea, Stephen Allen, Pete Walker
article en
6 citations

Abstract

Renewable bio-based materials are emerging technologies within the construction industry, providing inventive solutions for reducing material waste and the carbon footprint of an inherently carbon-intensive sector. Previously they have been commonly investigated in isolation and there are a significant lack of case studies demonstrating the performance of bio-based materials in entire external wall designs. This study evaluates the thermal and hygric performance of five novel bio-based external wall systems, featuring highly innovative combinations of insulation, structural and façade materials. Large scale wall panels were designed, constructed and tested within a bespoke Large Environmental Chamber (LEC) to determine thermal performance and hygric behaviour using the heat flow method. Hygrothermal simulations with WUFI® Pro were conducted to assess condensation and mould risks. Insulation materials used were wood fibre, mycelium, sheep's wool and blown-in cellulose. Structural options were timber, Cross Laminated Timber (CLT) and also light-gauge steel, while facades were bio-based-polymeric composite material or bio-based treated timber cladding. Thermal transmittance and conductance were calculated along with time series analysis of temperature and relative humidity . The U-values of the five walls ranged from 0.13 W/m 2 K to 0.22 W/m 2 K and modelling simulations were in broad agreement with the practical results, with four of the five walls fulfilling an 0.18 W/m 2 K benchmark value based upon building regulations. The significance of the study is in the demonstration of the feasibility of a range of bio-based external wall designs, combining emerging material technologies, innovative design and building physics to contribute to the development of bio-based construction. • Bio-based materials are emerging in buildings to provide external wall systems. • 5 innovative bio-based external wall designs are tested for hygrothermal properties. • Insulation materials used are sheep's wool, cellulose, wood fibre and mycelium. • U-values of the bio-based walls are in the range of 0.13 W/m 2 K to 0.22 W/m 2 K. • Two designs have been constructed as living laboratory buildings.

Journal of Building EngineeringVol. 101
Sustainability Institute (ZA), University of Bath (GB)
European Regional Development Fund, Interreg
Openalex Percentile: Top 7%
Plant and Biological Electrophysiology Studies
3.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.