Study of the Influence of Electromagnetic Fields on the Corrosion of District Heating Pipelines

One of the primary indicators influencing the dependability of the district heating system system is the corrosion of the pipeline surface. This article presents the findings of measurements and tests conducted on the example of the heat supply system in our country. The effects of electromagnetic fields on the surface corrosion of heat pipelines located in the area intersecting with high voltage lines and along overhead power lines are discussed. In the contemporary era, ecological concerns, including those pertaining to electromagnetic ecology, have emerged as a significant area of focus within the domains of science, technology, and socioeconomics. The study of the impact of energy pollution factors has led to the development of electromagnetic safety norms and standards. However, at the current stage, there is a lack of unified norms and standards for electromagnetic ecological assessment. Results of measurements indicate that the electric field strength is 0.38-32.33 V/m, while the magnetic field strength is 0.07-11.56 A/m. The voltage of the electric field is directly proportional to the voltage of the conductor. At the measurement point near the overhead power line (at a height of 1 m above the heat transmission line), the maximum voltage was 32.33 V/m. However, since the voltage of the magnetic field is directly proportional to the current running through the electric conductor, the current flowing through the conductor on the output of the extension generator had the highest value, resulting in the maximum magnetic field voltage of 11.56 A/m, which indicates that the measurement is accurate.

Authors

Institutions

Publication Details

Journal
Journal of Energy Transition
Published
2024-12-30
DOI
https://doi.org/10.59264/jet.v2i1.54
Citations
1
Primary Topic
Material Properties and Failure Mechanisms
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the Influence of Electromagnetic Fields on the Corrosion of District Heating Pipelines

Battulga Munkhbaatar, Pashka Byambatsogt, Tserendolgor Dugargaramjav
1 citations
Journal of Energy Transition
Material Properties and Failure Mechanisms
0.12
article

Study of the Influence of Electromagnetic Fields on the Corrosion of District Heating Pipelines

Battulga Munkhbaatar, Pashka Byambatsogt, Tserendolgor Dugargaramjav
article en
1 citations

Abstract

One of the primary indicators influencing the dependability of the district heating system system is the corrosion of the pipeline surface. This article presents the findings of measurements and tests conducted on the example of the heat supply system in our country. The effects of electromagnetic fields on the surface corrosion of heat pipelines located in the area intersecting with high voltage lines and along overhead power lines are discussed. In the contemporary era, ecological concerns, including those pertaining to electromagnetic ecology, have emerged as a significant area of focus within the domains of science, technology, and socioeconomics. The study of the impact of energy pollution factors has led to the development of electromagnetic safety norms and standards. However, at the current stage, there is a lack of unified norms and standards for electromagnetic ecological assessment. Results of measurements indicate that the electric field strength is 0.38-32.33 V/m, while the magnetic field strength is 0.07-11.56 A/m. The voltage of the electric field is directly proportional to the voltage of the conductor. At the measurement point near the overhead power line (at a height of 1 m above the heat transmission line), the maximum voltage was 32.33 V/m. However, since the voltage of the magnetic field is directly proportional to the current running through the electric conductor, the current flowing through the conductor on the output of the extension generator had the highest value, resulting in the maximum magnetic field voltage of 11.56 A/m, which indicates that the measurement is accurate.

Journal of Energy TransitionVol. 2(1)
Mongolian University of Science and Technology (MN)
Openalex Percentile: Top 56%
Material Properties and Failure Mechanisms
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of the Influence of Electromagnetic Fields on the Corrosion of District Heating Pipelines — Battulga Munkhbaatar, Pashka Byambatsogt, et al. · Journal of Energy Transition (2024) | TGRS Research Map | TGRS