Pulmonary artery pressure sensor device performance in patients with atrial fibrillation/flutter

Background: Previous studies have demonstrated that hemodynamic-guided management using implantable pulmonary artery (PA) pressure sensor device reduces heart failure (HF) hospitalizations in patients with HF. It is unclear if atrial fibrillation/flutter (AF) affect the performance of the PA pressure sensor.Methods: Using the National Readmission Database (NRD) we examined 90-day HF-specific and all-cause readmission in patients with and without AF after PA pressure sensor implantation in the US from 2016 to 2020 in a propensity score matched analysis. Our cohort comprised of adult patients (≥18 years) with an ICD-10 procedural code for PA pressure sensor implantation. Results: We included 1515 hospitalizations with PA sensor implantation for 90-day readmission analysis. Among patients implanted with the PA pressure sensor, 17.2% of patients without AF and 16.3% of patients with AF were readmitted primarily for HF within 90-days of discharge (Adjusted OR: 1.07, 95% CI 0.61 – 1.87, p = 0.800). Whereas, 36.3% of patients without AF and 33.9% of patients with AF were readmitted for any cause within 90-days of discharge (Adjusted OR: 0.85, 95% CI 0.53 – 1.37, p = 0.505). In subgroup analysis, there was no difference in HF-specific or all-cause readmission in AF patients with HF with reduced ejection fraction or HF with preserved ejection fraction when compared to those without AF.Conclusions: Analysis of a large, real-world cohort of HF patients with implantable PA pressure sensor showed that HF-specific and all-cause readmissions at 90 days after PA pressure sensor implantation were comparable between patients with and without AF.

Authors

Institutions

Publication Details

Journal
Global Cardiology
Published
2024-12-30
DOI
https://doi.org/10.4081/cardio.2024.55
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary artery pressure sensor device performance in patients with atrial fibrillation/flutter

Jafar A. Alzubi, Razan Alrawashdeh, Mohammad Al Madani, Muhammad Usman Almani et al.
Global Cardiology
Cardiac Arrhythmias and Treatments
article

Pulmonary artery pressure sensor device performance in patients with atrial fibrillation/flutter

Jafar A. Alzubi, Razan Alrawashdeh, Mohammad Al Madani, Muhammad Usman Almani, Muhammad Yousuf, Raphael Bonita, Noor Fatima
article en

Abstract

Background: Previous studies have demonstrated that hemodynamic-guided management using implantable pulmonary artery (PA) pressure sensor device reduces heart failure (HF) hospitalizations in patients with HF. It is unclear if atrial fibrillation/flutter (AF) affect the performance of the PA pressure sensor.Methods: Using the National Readmission Database (NRD) we examined 90-day HF-specific and all-cause readmission in patients with and without AF after PA pressure sensor implantation in the US from 2016 to 2020 in a propensity score matched analysis. Our cohort comprised of adult patients (≥18 years) with an ICD-10 procedural code for PA pressure sensor implantation. Results: We included 1515 hospitalizations with PA sensor implantation for 90-day readmission analysis. Among patients implanted with the PA pressure sensor, 17.2% of patients without AF and 16.3% of patients with AF were readmitted primarily for HF within 90-days of discharge (Adjusted OR: 1.07, 95% CI 0.61 – 1.87, p = 0.800). Whereas, 36.3% of patients without AF and 33.9% of patients with AF were readmitted for any cause within 90-days of discharge (Adjusted OR: 0.85, 95% CI 0.53 – 1.37, p = 0.505). In subgroup analysis, there was no difference in HF-specific or all-cause readmission in AF patients with HF with reduced ejection fraction or HF with preserved ejection fraction when compared to those without AF.Conclusions: Analysis of a large, real-world cohort of HF patients with implantable PA pressure sensor showed that HF-specific and all-cause readmissions at 90 days after PA pressure sensor implantation were comparable between patients with and without AF.

Global CardiologyVol. 2(4)
Yale New Haven Hospital (US), Nishtar Medical College and Hospital (PK), Detroit Medical Center (US), Jefferson Einstein Philadelphia Hospital (US), Mayo Clinic in Arizona (US), Jefferson Hospital (US)
Openalex Percentile: Top 56%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.