DiffTune-PI Based Vector Control of Doubly Fed Induction Generator for Grid-Connected Operation

Due to the unstable feature of wind energy, fixed parameter control cannot adequately meet the demand of doubly fed induction generator (DFIG) system for wind power generation. In this paper, for the control of DFIG under grid-connected operation conditions, a vector control method with stator voltage orientation based on DifITune- PI algorithm is proposed. The control parameters of the PI controller are optimized online by the DifITune algorithm and the disturbance term is compensated through feed-forward compensation. Simulation results show that the proposed method can effectively suppress the power and voltage fluctuations of the DFIG system under grid-connected operation conditions with excellent dynamic and static performances when generator starts, the grid voltage drops and the input wind speed decreases.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/icist63249.2024.10805435
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DiffTune-PI Based Vector Control of Doubly Fed Induction Generator for Grid-Connected Operation

Gaihui Wang, Zhouhua Peng, Liyu Lu, Zhiwei Li et al.
1 links
Multilevel Inverters and Converters
article

DiffTune-PI Based Vector Control of Doubly Fed Induction Generator for Grid-Connected Operation

Gaihui Wang, Zhouhua Peng, Liyu Lu, Zhiwei Li, Haoliang Wang, Dan Wang
article en

Abstract

Due to the unstable feature of wind energy, fixed parameter control cannot adequately meet the demand of doubly fed induction generator (DFIG) system for wind power generation. In this paper, for the control of DFIG under grid-connected operation conditions, a vector control method with stator voltage orientation based on DifITune- PI algorithm is proposed. The control parameters of the PI controller are optimized online by the DifITune algorithm and the disturbance term is compensated through feed-forward compensation. Simulation results show that the proposed method can effectively suppress the power and voltage fluctuations of the DFIG system under grid-connected operation conditions with excellent dynamic and static performances when generator starts, the grid voltage drops and the input wind speed decreases.

Changjiang Institute of Survey, Planning, Design and Research (CN), Dalian Maritime University (CN)
Affordable and clean energy
Openalex Percentile: Top 77%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.