Research on Impedance Matching for Improving Gain in Conductive Intracardiac Communication

As an emerging method of intracardiac wireless communication, conductive intracardiac communication (CIC) has the advantages of low power consumption and high security of information transmission, and is suitable for synchronization between multiple leadless pacemakers (LCPs). However, the complicated intracardiac environment increases the measurement uncertainty of intracardiac channel parameters, and current research on intracardiac communication does not take into account impedance mismatch. These may lead to unreliable communication between LCPs. In this paper, an equivalent circuit model of the intracardiac channel is constructed based on the electrical characteristics of cardiac tissue. The intracardiac channel uses an L-type impedance matching circuit to improve the channel gain. The results show that the channel gain increases by more than 7 dB after adding the impedance matching circuit. Especially, the most significant increase is 8.33 dB at 10MHz. This proves the feasibility of the impedance matching method and provides an effective solution for the future design of intracardiac communication transceivers.

Authors

Institutions

Publication Details

Published
2024-11-04
DOI
https://doi.org/10.1109/csrswtc64338.2024.10811485
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Impedance Matching for Improving Gain in Conductive Intracardiac Communication

Jiamei Wang, Yueming Gao, Mang I Vai, Sio Hang Pun et al.
ECG Monitoring and Analysis
article

Research on Impedance Matching for Improving Gain in Conductive Intracardiac Communication

Jiamei Wang, Yueming Gao, Mang I Vai, Sio Hang Pun, Dongming Li, Jiejie Yang, Han Wang
article en

Abstract

As an emerging method of intracardiac wireless communication, conductive intracardiac communication (CIC) has the advantages of low power consumption and high security of information transmission, and is suitable for synchronization between multiple leadless pacemakers (LCPs). However, the complicated intracardiac environment increases the measurement uncertainty of intracardiac channel parameters, and current research on intracardiac communication does not take into account impedance mismatch. These may lead to unreliable communication between LCPs. In this paper, an equivalent circuit model of the intracardiac channel is constructed based on the electrical characteristics of cardiac tissue. The intracardiac channel uses an L-type impedance matching circuit to improve the channel gain. The results show that the channel gain increases by more than 7 dB after adding the impedance matching circuit. Especially, the most significant increase is 8.33 dB at 10MHz. This proves the feasibility of the impedance matching method and provides an effective solution for the future design of intracardiac communication transceivers.

University of Macau (MO), Fuzhou University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 56%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Impedance Matching for Improving Gain in Conductive Intracardiac Communication — Jiamei Wang, Yueming Gao, et al. · (2024) | TGRS Research Map | TGRS