Vernier-Effect-Based Fiber Microcoupler for Salinity Measurement

A highly sensitive fiber optic multimode coupler for salinity measurement based on Vernier effect is proposed. The coupler is manufactured by tapering two single-mode optical fiber whose sides touch each other. By controlling the shape of the coupler in the waist region, the enveloped interference spectrum caused by the Vernier effect can be observed. Compared with the common interference spectrum of a coupler, this enveloped spectrum exhibits a higher refractive index sensitivity. The experimental results show that the sample of this coupler could achieve a salinity sensitivity of 1.742nm/%o in the measurement range from 0% o to 50% o, and the magnification factor is about 2.93. This high-sensitivity, low-cost coupler can be applied to salinity or refractive index related measurements in industrial and marine fields.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1109/icait62580.2024.10808004
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vernier-Effect-Based Fiber Microcoupler for Salinity Measurement

Keyi Liu, Yaqi Tang, Chao Wang, Junfeng Chen et al.
Advanced Fiber Optic Sensors
article

Vernier-Effect-Based Fiber Microcoupler for Salinity Measurement

Keyi Liu, Yaqi Tang, Chao Wang, Junfeng Chen, Wei Jin, Chenguang Li, Xinyi Liu, Si-tong Lin
article en

Abstract

A highly sensitive fiber optic multimode coupler for salinity measurement based on Vernier effect is proposed. The coupler is manufactured by tapering two single-mode optical fiber whose sides touch each other. By controlling the shape of the coupler in the waist region, the enveloped interference spectrum caused by the Vernier effect can be observed. Compared with the common interference spectrum of a coupler, this enveloped spectrum exhibits a higher refractive index sensitivity. The experimental results show that the sample of this coupler could achieve a salinity sensitivity of 1.742nm/%o in the measurement range from 0% o to 50% o, and the magnification factor is about 2.93. This high-sensitivity, low-cost coupler can be applied to salinity or refractive index related measurements in industrial and marine fields.

Hong Kong Polytechnic University (HK), Shenzhen Technology University (CN), Beijing University of Chemical Technology (CN)
Zero hunger
Openalex Percentile: Top 77%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.