New 2D Thermal Model for Shell-Type Medium Frequency Transformers and Experimental Validation Thereof

Medium Frequency Transformers are essential for achieving galvanic isolation in isolated converter topologies, but challenges in insulation and cooling arise due to their compact nature. This study introduces a versatile thermal circuit tailored for shell-type medium frequency transformers. By addressing dielectric losses and incorporating diverse insulation materials, heatsink integration, and air gap considerations, this research enhances the adaptability of thermal modeling in the design process. The derived analytical model is verified against measurements from a 5kW test bench featuring a solid insulated transformer prototype, with a maximum hotspot relative error not exceeding 11.1% at all tested operating conditions.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.1109/dmc62632.2024.10812149
Citations
3
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New 2D Thermal Model for Shell-Type Medium Frequency Transformers and Experimental Validation Thereof

Ahmed Meligy, Rafael Coelho-Medeiros, Seddik Bacha, Ilknur Colak et al.
3 citations
Advanced DC-DC Converters
0.63
article

New 2D Thermal Model for Shell-Type Medium Frequency Transformers and Experimental Validation Thereof

Ahmed Meligy, Rafael Coelho-Medeiros, Seddik Bacha, Ilknur Colak, Caroline Stackler, Jules Twizeyimana
article en
3 citations

Abstract

Medium Frequency Transformers are essential for achieving galvanic isolation in isolated converter topologies, but challenges in insulation and cooling arise due to their compact nature. This study introduces a versatile thermal circuit tailored for shell-type medium frequency transformers. By addressing dielectric losses and incorporating diverse insulation materials, heatsink integration, and air gap considerations, this research enhances the adaptability of thermal modeling in the design process. The derived analytical model is verified against measurements from a 5kW test bench featuring a solid insulated transformer prototype, with a maximum hotspot relative error not exceeding 11.1% at all tested operating conditions.

Institut polytechnique de Grenoble (FR), Centre National de la Recherche Scientifique (FR), Schneider Electric (France) (FR), Schneider Electric (Germany) (DE), Laboratoire de Génie Électrique de Grenoble (FR), Université Grenoble Alpes (FR)
Affordable and clean energy
Openalex Percentile: Top 30%
Advanced DC-DC Converters
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.