Power Integrity Analysis of a Power Line Between a DDR4 Memory and a Controller

Power integrity (PI) is a highly debated topic in the electronics industry as it can exhibit a substantial range of problems, each with its unique causes and solutions. The field of PI encompasses everything from voltage regulator modules to on-die capacitance and on-die core power rails. In this paper, an analysis on PI of a power rail by running DC drop and decoupling simulations using the HyperLynx was performed. Using this tool, the placement and size of the decoupling capacitors was performed. The DC drop simulations for different board temperatures were done to obtain all the DC drop characteristics of the proposed design. For the decoupling simulation the impedance properties of the designed power rail referencing a predetermined target impedance were obtained.

Authors

Institutions

Publication Details

Published
2024-10-16
DOI
https://doi.org/10.1109/siitme63973.2024.10814742
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Integrity Analysis of a Power Line Between a DDR4 Memory and a Controller

Mihai Daraban, A. I. Marina
Electromagnetic Compatibility and Noise Suppression
article

Power Integrity Analysis of a Power Line Between a DDR4 Memory and a Controller

Mihai Daraban, A. I. Marina
article en

Abstract

Power integrity (PI) is a highly debated topic in the electronics industry as it can exhibit a substantial range of problems, each with its unique causes and solutions. The field of PI encompasses everything from voltage regulator modules to on-die capacitance and on-die core power rails. In this paper, an analysis on PI of a power rail by running DC drop and decoupling simulations using the HyperLynx was performed. Using this tool, the placement and size of the decoupling capacitors was performed. The DC drop simulations for different board temperatures were done to obtain all the DC drop characteristics of the proposed design. For the decoupling simulation the impedance properties of the designed power rail referencing a predetermined target impedance were obtained.

Technical University of Cluj-Napoca (RO)
Affordable and clean energy
Openalex Percentile: Top 77%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.