Lightning Response on Cable Core and Sheath in Single-Circuit Underground Cable

Throughout their operational lifespan, underground cables (UGCs) encounter diverse transient phenomena, with lightning strikes being of notable concern, particularly for hybrid cable-overhead lines . Lightning impulses wield significant influence, particularly at the termination section where the underground line meets the overhead line. This study investigates the effects of lightning strikes on both the cable sheaths and the core. The study evaluates the impact of generalized formulations developed by Xue and simplified formulations developed by Pollaczek for line parameter calculations. Furthermore, the study considers the inclusion of soil parameters dependent on frequency. Two scenarios are examined: a theoretical scenario where sheaths are presumed disconnected from the ground and a more realistic scenario where sheaths are short-circuited and grounded. The results indicate that in the theoretical scenario, the percentage deviation reaches 110.7% in the cable core of phase B. Conversely, in the more realistic scenario, a maximum percentage deviation of 68.4% is observed in the sheaths when utilizing the Pollaczek formulation.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1109/wcnps65035.2024.10814147
Citations
5
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
1.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightning Response on Cable Core and Sheath in Single-Circuit Underground Cable

José Pissolato Filho, Jaimis S. L. Colqui, Filipe Faria da Silva, Jesus E. Guevara Asorza
5 citations
Lightning and Electromagnetic Phenomena
1.66
article

Lightning Response on Cable Core and Sheath in Single-Circuit Underground Cable

José Pissolato Filho, Jaimis S. L. Colqui, Filipe Faria da Silva, Jesus E. Guevara Asorza
article en
5 citations

Abstract

Throughout their operational lifespan, underground cables (UGCs) encounter diverse transient phenomena, with lightning strikes being of notable concern, particularly for hybrid cable-overhead lines . Lightning impulses wield significant influence, particularly at the termination section where the underground line meets the overhead line. This study investigates the effects of lightning strikes on both the cable sheaths and the core. The study evaluates the impact of generalized formulations developed by Xue and simplified formulations developed by Pollaczek for line parameter calculations. Furthermore, the study considers the inclusion of soil parameters dependent on frequency. Two scenarios are examined: a theoretical scenario where sheaths are presumed disconnected from the ground and a more realistic scenario where sheaths are short-circuited and grounded. The results indicate that in the theoretical scenario, the percentage deviation reaches 110.7% in the cable core of phase B. Conversely, in the more realistic scenario, a maximum percentage deviation of 68.4% is observed in the sheaths when utilizing the Pollaczek formulation.

Universidade Estadual de Campinas (UNICAMP) (BR), Aalborg University (DK)
Climate action
Openalex Percentile: Top 16%
Lightning and Electromagnetic Phenomena
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lightning Response on Cable Core and Sheath in Single-Circuit Underground Cable — José Pissolato Filho, Jaimis S. L. Colqui, et al. · (2024) | TGRS Research Map | TGRS