OpenDER Model: Assessing IEEE Std 1547-2018 Voltage/Power Control Functions

This paper evaluates the OpenDER model’s performance in simulating inverter-based distributed energy resources (DERs) using IEEE Std 1547-2018 control modes. Integrated with OpenDSS via Python, the OpenDER model is assessed under Constant Power Factor, Volt-VAr, Watt-VAr, Constant Reactive Power, and Volt-Watt modes. Results reveal the model’s effectiveness in maintaining power factor and adjusting reactive power. The results demonstrate the model’s effectiveness in following the control curves proposed by IEEE Std 1547-2018, with only minor deviations in some cases, such as the Volt-VAR curve. Additionally, the differences between Categories A and B are highlighted for the same operating mode, which, in turn, affects the feeder voltage at the DER connection node. The dynamic DER response to voltage deviations is also presented, showing its ability to transition between Mandatory and Continuous Operation modes. The findings highlight the model’s strengths and areas for improvement, offering insights for better DER integration in power systems.

Authors

Institutions

Publication Details

Published
2024-12-12
DOI
https://doi.org/10.1109/wcnps65035.2024.10814168
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OpenDER Model: Assessing IEEE Std 1547-2018 Voltage/Power Control Functions

Murillo Cobe Vargas, Clainer Bravin Donadel, Rui Lima
Fault Detection and Control Systems
article

OpenDER Model: Assessing IEEE Std 1547-2018 Voltage/Power Control Functions

Murillo Cobe Vargas, Clainer Bravin Donadel, Rui Lima
article en

Abstract

This paper evaluates the OpenDER model’s performance in simulating inverter-based distributed energy resources (DERs) using IEEE Std 1547-2018 control modes. Integrated with OpenDSS via Python, the OpenDER model is assessed under Constant Power Factor, Volt-VAr, Watt-VAr, Constant Reactive Power, and Volt-Watt modes. Results reveal the model’s effectiveness in maintaining power factor and adjusting reactive power. The results demonstrate the model’s effectiveness in following the control curves proposed by IEEE Std 1547-2018, with only minor deviations in some cases, such as the Volt-VAR curve. Additionally, the differences between Categories A and B are highlighted for the same operating mode, which, in turn, affects the feeder voltage at the DER connection node. The dynamic DER response to voltage deviations is also presented, showing its ability to transition between Mandatory and Continuous Operation modes. The findings highlight the model’s strengths and areas for improvement, offering insights for better DER integration in power systems.

Instituto Federal do Espírito Santo (BR)
Fundação de Amparo à Pesquisa e Inovação do Espírito Santo
Affordable and clean energy
Openalex Percentile: Top 70%
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.