Study of Temperature Growth in Ceiling of Large-Space Compartment through Full-Scale Combustion Experiment

In this study, a full-scale combustion experiment was conducted to analyze the temperature growth in a large-space compartment where the entire compartment may not be exposed to flames and the combustibles do not burn completely. The full-scale combustion experiment was performed using ethanol as fuel, in a compartment with a steel frame measuring 5.0 (L) × 25 (W) × 5.0 (H) m, where twelve burners, each measuring 0.45 (L) × 0.45 (W) × 0.1 (H) m, were arranged. The experiment was conducted using two methods: simultaneous ignition of all the burners and ignition at regular intervals. The temperature changes were measured at 53 points on the ceiling. As a result of the experiment, the maximum temperature near the fire source in simultaneous ignition was 252.3 °C, while in delayed ignition, it reached 181.0 °C near the fire source. Additionally, at approximately 14.5 meters from the fire source, a sharp temperature drop followed by an increase was observed, indicating a characteristic division between the near-field region close to the fire source and the far-field region near the exit.

Authors

Institutions

Publication Details

Journal
Fire Science and Engineering
Published
2024-12-31
DOI
https://doi.org/10.7731/kifse.5e1a1bf7
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Temperature Growth in Ceiling of Large-Space Compartment through Full-Scale Combustion Experiment

Oh-Sang Kweon
Fire Science and Engineering
Fire dynamics and safety research
article

Study of Temperature Growth in Ceiling of Large-Space Compartment through Full-Scale Combustion Experiment

Oh-Sang Kweon
article en

Abstract

In this study, a full-scale combustion experiment was conducted to analyze the temperature growth in a large-space compartment where the entire compartment may not be exposed to flames and the combustibles do not burn completely. The full-scale combustion experiment was performed using ethanol as fuel, in a compartment with a steel frame measuring 5.0 (L) × 25 (W) × 5.0 (H) m, where twelve burners, each measuring 0.45 (L) × 0.45 (W) × 0.1 (H) m, were arranged. The experiment was conducted using two methods: simultaneous ignition of all the burners and ignition at regular intervals. The temperature changes were measured at 53 points on the ceiling. As a result of the experiment, the maximum temperature near the fire source in simultaneous ignition was 252.3 °C, while in delayed ignition, it reached 181.0 °C near the fire source. Additionally, at approximately 14.5 meters from the fire source, a sharp temperature drop followed by an increase was observed, indicating a characteristic division between the near-field region close to the fire source and the far-field region near the exit.

Fire Science and EngineeringVol. 38(6)
Fire Safety Design (SE)
Affordable and clean energy
Openalex Percentile: Top 70%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of Temperature Growth in Ceiling of Large-Space Compartment through Full-Scale Combustion Experiment — Oh-Sang Kweon · Fire Science and Engineering (2024) | TGRS Research Map | TGRS