External Exposure Experiment and Condensation Detection Method for Air Sampling Smoke Detectors in Freezer Storage

In this study, a pipe temperature characteristics test and a condensation detection method were conducted for each area of the air sampling smoke detector in the freezer. Among the temperature gradient experiments for each zone, the maximum temperature differences were as follows: Zone 1: –6.8 ℃, Zone 2: –0.7 ℃, Zone 3: –0.3 ℃, and Zone 4: 5.8 ℃, indicating the largest temperature difference between the outdoor contact part and the area exposed to the wind side of the cooler. In areas with large temperature gradients, condensation and freezing occurred in the air-sampling smoke detector pipe. In an experiment to detect condensation in an air suction-type pipe using a pressure sensor, a measurement of 1,058 mV was recorded by the pressure sensor during the operation of an air-sampling smoke detector fan with a standardized airflow. When freezing occurred at the pipe inlet due to condensation, we confirmed that the voltage increased by 1,069 mV in one location, 1,099 mV in three locations, and 1,110 mV in five locations. Accordingly, we believe that by transmitting the voltage signal from the pressure sensor due to the pressure drop caused by condensation, the flow rate and pressure status of the pipe can be monitored, allowing for maintenance based on abnormal signals.

Authors

Publication Details

Journal
Fire Science and Engineering
Published
2024-12-31
DOI
https://doi.org/10.7731/kifse.7c7adc2b
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External Exposure Experiment and Condensation Detection Method for Air Sampling Smoke Detectors in Freezer Storage

Su-Gil Choi, Gunho Lee
Fire Science and Engineering
Fire Detection and Safety Systems
article

External Exposure Experiment and Condensation Detection Method for Air Sampling Smoke Detectors in Freezer Storage

Su-Gil Choi, Gunho Lee
article en

Abstract

In this study, a pipe temperature characteristics test and a condensation detection method were conducted for each area of the air sampling smoke detector in the freezer. Among the temperature gradient experiments for each zone, the maximum temperature differences were as follows: Zone 1: –6.8 ℃, Zone 2: –0.7 ℃, Zone 3: –0.3 ℃, and Zone 4: 5.8 ℃, indicating the largest temperature difference between the outdoor contact part and the area exposed to the wind side of the cooler. In areas with large temperature gradients, condensation and freezing occurred in the air-sampling smoke detector pipe. In an experiment to detect condensation in an air suction-type pipe using a pressure sensor, a measurement of 1,058 mV was recorded by the pressure sensor during the operation of an air-sampling smoke detector fan with a standardized airflow. When freezing occurred at the pipe inlet due to condensation, we confirmed that the voltage increased by 1,069 mV in one location, 1,099 mV in three locations, and 1,110 mV in five locations. Accordingly, we believe that by transmitting the voltage signal from the pressure sensor due to the pressure drop caused by condensation, the flow rate and pressure status of the pipe can be monitored, allowing for maintenance based on abnormal signals.

Fire Science and EngineeringVol. 38(6)
Affordable and clean energy
Openalex Percentile: Top 70%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

External Exposure Experiment and Condensation Detection Method for Air Sampling Smoke Detectors in Freezer Storage — Su-Gil Choi, Gunho Lee · Fire Science and Engineering (2024) | TGRS Research Map | TGRS