Research on calibration method and uncertainty evaluation of thermal gas mass flowmeter

The thermal mass flowmeter has simple structure and wide measurement range. It can be divided into capillary thermal mass flowmeter and plug-in thermal mass flowmeter. In order to accurately measure the thermal gas mass flowmeter, the passive gas piston provers (standard device) was selected to measure it. and the measurement uncertainty of the standard device was analyzed. Three test points are selected to test at three pistons, and the repeatability of the measurement results and the expanded uncertainty of the measurement results are analyzed at the same time. The expanded uncertainty <i>U</i><sub>rel</sub> is 0.19% (<i>k</i>=2), which is proved that the calibration of the thermal gas mass flowmeter with passive gas piston provers (standard device) is effective. The uncertainty of the measurement results is small and the reliability is high.

Authors

Institutions

Publication Details

Published
2024-12-30
DOI
https://doi.org/10.1117/12.3052515
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on calibration method and uncertainty evaluation of thermal gas mass flowmeter

Menglan He, Yichun Bai, Xing Liu, Lulu Zhang et al.
Flow Measurement and Analysis
article

Research on calibration method and uncertainty evaluation of thermal gas mass flowmeter

Menglan He, Yichun Bai, Xing Liu, Lulu Zhang, Zhong-Zhi Yang
article en

Abstract

The thermal mass flowmeter has simple structure and wide measurement range. It can be divided into capillary thermal mass flowmeter and plug-in thermal mass flowmeter. In order to accurately measure the thermal gas mass flowmeter, the passive gas piston provers (standard device) was selected to measure it. and the measurement uncertainty of the standard device was analyzed. Three test points are selected to test at three pistons, and the repeatability of the measurement results and the expanded uncertainty of the measurement results are analyzed at the same time. The expanded uncertainty <i>U</i><sub>rel</sub> is 0.19% (<i>k</i>=2), which is proved that the calibration of the thermal gas mass flowmeter with passive gas piston provers (standard device) is effective. The uncertainty of the measurement results is small and the reliability is high.

Chongqing Metrology Quality Inspection and Research Institute (CN)
Openalex Percentile: Top 72%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.