New capabilities for the realisation and the dissemination of the kelvin at high temperature in Europe

The Mise-en-Pratique for the recent redefinition of the kelvin has opened the possibility to directly disseminate the thermodynamic temperature by the mean of high-temperature fixed points whose thermodynamic temperature was assigned once and for all. These newly characterised fixed points offer to NMIs and DIs the possibility to perform a temperature scale directly linked to a thermodynamic temperature, without the complexity of an absolute measurement and without the need for extensive characterisation of the pyrometer performing the extrapolation. This article describes the various stages of the European project “Realising the redefined kelvin”, aimed at opening up these new possibilities to European laboratories.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-30
DOI
https://doi.org/10.1016/j.measen.2024.101624
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New capabilities for the realisation and the dissemination of the kelvin at high temperature in Europe

F. Bourson, Åge Andreas Falnes Olsen, M. Sadli, L. Kňazovická et al.
Measurement Sensors
Calibration and Measurement Techniques
article

New capabilities for the realisation and the dissemination of the kelvin at high temperature in Europe

F. Bourson, Åge Andreas Falnes Olsen, M. Sadli, L. Kňazovická, P. Pavlásek, Humbet Nasibli
article en

Abstract

The Mise-en-Pratique for the recent redefinition of the kelvin has opened the possibility to directly disseminate the thermodynamic temperature by the mean of high-temperature fixed points whose thermodynamic temperature was assigned once and for all. These newly characterised fixed points offer to NMIs and DIs the possibility to perform a temperature scale directly linked to a thermodynamic temperature, without the complexity of an absolute measurement and without the need for extensive characterisation of the pyrometer performing the extrapolation. This article describes the various stages of the European project “Realising the redefined kelvin”, aimed at opening up these new possibilities to European laboratories.

Measurement SensorsVol. 38
Conservatoire National des Arts et Métiers (FR), Norwegian Metrology Service (NO), Laboratoire National de Métrologie et d'Essais (FR), Tübitak National Metrology Institute (TR), Český metrologický institut (CZ), Slovenský Metrologický Ústav (SK)
Climate action
Openalex Percentile: Top 59%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines