MRI Motion Correction Through Disentangled CycleGAN Based on Multi-Mask K-Space Subsampling

This work proposes a new retrospective motion correction method, termed DCGAN-MS, which employs disentangled CycleGAN based on multi-mask k-space subsampling (DCGAN-MS) to address the image domain translation challenge. The multi-mask k-space subsampling operator is utilized to decrease the complexity of motion artifacts by randomly discarding motion-affected k-space lines. The network then disentangles the subsampled, motion-corrupted images into content and artifact features using specialized encoders, and generates motion-corrected images by decoding the content features. By utilizing multi-mask k-space subsampling, motion artifact features become more sparse compared to the original image domain, enhancing the efficiency of the DCGAN-MS network. This method effectively corrects motion artifacts in clinical gadoxetic acid-enhanced human liver MRI, human brain MRI from fastMRI, and preclinical rodent brain MRI. Quantitative improvements are demonstrated with SSIM values increasing from 0.75 to 0.86 for human liver MRI with simulated motion artifacts, and from 0.72 to 0.82 for rodent brain MRI with simulated motion artifacts. Correspondingly, PSNR values increased from 26.09 to 31.09 and from 25.10 to 31.77. The method's performance was further validated on clinical and preclinical motion-corrupted MRI using the Kernel Inception Distance (KID) and Fréchet Inception Distance (FID) metrics. Additionally, ablation experiments were conducted to confirm the effectiveness of the multi-mask k-space subsampling approach.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2024-12-30
DOI
https://doi.org/10.1109/tmi.2024.3523949
Citations
4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI Motion Correction Through Disentangled CycleGAN Based on Multi-Mask K-Space Subsampling

Qingjia Bao, Feng Pan, Maili Liu, Mārtiņš Otikovs et al.
4 citations
IEEE Transactions on Medical Imaging
Advanced MRI Techniques and Applications
1.62
article

MRI Motion Correction Through Disentangled CycleGAN Based on Multi-Mask K-Space Subsampling

Qingjia Bao, Feng Pan, Maili Liu, Mārtiņš Otikovs, Xinping Rao, Zhi Long Zhang, Lucio Frydman, Xin Hua Zhou, Gang Chen, Peng Sun, Lian Yang, Chaoyang Liu, Xie Han, Xinjie Liu
article en
4 citations

Abstract

This work proposes a new retrospective motion correction method, termed DCGAN-MS, which employs disentangled CycleGAN based on multi-mask k-space subsampling (DCGAN-MS) to address the image domain translation challenge. The multi-mask k-space subsampling operator is utilized to decrease the complexity of motion artifacts by randomly discarding motion-affected k-space lines. The network then disentangles the subsampled, motion-corrupted images into content and artifact features using specialized encoders, and generates motion-corrected images by decoding the content features. By utilizing multi-mask k-space subsampling, motion artifact features become more sparse compared to the original image domain, enhancing the efficiency of the DCGAN-MS network. This method effectively corrects motion artifacts in clinical gadoxetic acid-enhanced human liver MRI, human brain MRI from fastMRI, and preclinical rodent brain MRI. Quantitative improvements are demonstrated with SSIM values increasing from 0.75 to 0.86 for human liver MRI with simulated motion artifacts, and from 0.72 to 0.82 for rodent brain MRI with simulated motion artifacts. Correspondingly, PSNR values increased from 26.09 to 31.09 and from 25.10 to 31.77. The method's performance was further validated on clinical and preclinical motion-corrupted MRI using the Kernel Inception Distance (KID) and Fréchet Inception Distance (FID) metrics. Additionally, ablation experiments were conducted to confirm the effectiveness of the multi-mask k-space subsampling approach.

IEEE Transactions on Medical ImagingVol. 44(4)
Union Hospital (HK), Chinese Academy of Sciences (CN), Philips (China) (CN), Wuhan Institute of Physics and Mathematics (CN), China Railway Construction Machinery Research & Design Institute (CN), Huazhong University of Science and Technology (CN), Weizmann Institute of Science (IL)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 15%
Advanced MRI Techniques and Applications
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.