Metacontrast masking does not change with different display technologies: A comparison of CRT and LCD monitors

Most vision labs have had to replace the formerly dominant CRT screens with LCDs and several studies have investigated whether changing the display type leads to changes in perceptual phenomena, since fundamental properties of the stimulation, e.g., the transition time between frames, differ between these different display technologies. While many phenomena have proven robust, Kihara et al. (2010) reported different metacontrast masking functions on LCDs compared to CRTs. This difference poses a challenge for the integration of new LCD-based findings with the established knowledge from studies with CRTs and requires theoretical accounts that consider the effects of different display types. However, before further conclusions can be drawn, the basic findings should be secured. Therefore, we tried to reproduce the display type effect by comparing metacontrast masking on an LCD and a CRT in two experiments. Our approach differs from the previous study by increasing the power and reliability of the measurements and carefully matching the two display types. In addition to display type, we varied target-mask stimulus-onset asynchrony (SOA) and stimulus-background polarity. Regardless of display type and polarity, we found the typical type-B masking functions. Evidence for a SOA-dependent display type effect in the black-on-white polarity condition from Experiment 1 was not replicated in Experiment 2. Overall, the results indicate that metacontrast masking effects on objective and subjective measurements, i.e., discriminatory sensitivity and phenomenological reports, do not vary significantly with display technologies. This lack of display effects is discussed in the context of current theories of metacontrast masking.

Authors

Institutions

Publication Details

Journal
Behavior Research Methods
Published
2024-12-30
DOI
https://doi.org/10.3758/s13428-024-02526-w
Citations
1
Primary Topic
Color Science and Applications
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metacontrast masking does not change with different display technologies: A comparison of CRT and LCD monitors

Uwe Mattler, Thorsten Albrecht, Tomke Hajo Eike Klaas Trußner
1 citations
Behavior Research Methods
Color Science and Applications
0.34
article

Metacontrast masking does not change with different display technologies: A comparison of CRT and LCD monitors

Uwe Mattler, Thorsten Albrecht, Tomke Hajo Eike Klaas Trußner
article en
1 citations

Abstract

Most vision labs have had to replace the formerly dominant CRT screens with LCDs and several studies have investigated whether changing the display type leads to changes in perceptual phenomena, since fundamental properties of the stimulation, e.g., the transition time between frames, differ between these different display technologies. While many phenomena have proven robust, Kihara et al. (2010) reported different metacontrast masking functions on LCDs compared to CRTs. This difference poses a challenge for the integration of new LCD-based findings with the established knowledge from studies with CRTs and requires theoretical accounts that consider the effects of different display types. However, before further conclusions can be drawn, the basic findings should be secured. Therefore, we tried to reproduce the display type effect by comparing metacontrast masking on an LCD and a CRT in two experiments. Our approach differs from the previous study by increasing the power and reliability of the measurements and carefully matching the two display types. In addition to display type, we varied target-mask stimulus-onset asynchrony (SOA) and stimulus-background polarity. Regardless of display type and polarity, we found the typical type-B masking functions. Evidence for a SOA-dependent display type effect in the black-on-white polarity condition from Experiment 1 was not replicated in Experiment 2. Overall, the results indicate that metacontrast masking effects on objective and subjective measurements, i.e., discriminatory sensitivity and phenomenological reports, do not vary significantly with display technologies. This lack of display effects is discussed in the context of current theories of metacontrast masking.

Behavior Research MethodsVol. 57(1)
University of Göttingen (DE)
Deutsche Forschungsgemeinschaft, Georg-August-Universität Göttingen
Reduced inequalities
Openalex Percentile: Top 37%
Color Science and Applications
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Metacontrast masking does not change with different display technologies: A comparison of CRT and LCD monitors — Uwe Mattler, Thorsten Albrecht, et al. · Behavior Research Methods (2024) | TGRS Research Map | TGRS