Highly sensitive carboxyl group fluorimetric derivatization HPLC analysis for rosuvastatin content in tablets

Background and Aims: The powerful antihyperlipidemic drug rosuvastatin blocks 3-hydroxy-3-methylglutaryl coenzyme A reductase, which is essential for cholesterol formation. Statins are a more recent class of antihyperlipidemic medications. Accurate quantification methods are crucial because of low rosuvastatin levels in tablets. The following the International Conference on Harmonisation (ICH) guidelines, a sensitive and high-performance liquid chromatographic approach was established in this study for the accurate determination of rosuvastatin in tablet formulations using spectrofluorimetric detection. Methods: The procedure requires one hour at room temperature and dark interaction between the acid group of rosuvastatin and the reagent 9-anthryldiazomethane. A C18 column (250 x 4.6 mm, 4 μm) was used for the gradient elution of an acetonitrile-water solution at a flow rate of 1.0 mL/min to achieve chromatographic separation. The internal reference was lovastatin. The excitation and emission wavelengths used for the detection were 366 and 410 nm, respectively. Results: Calibration curves for standard solutions were established by plotting the ratio of concentration to peak area over the range 0.01–20.0 ng/mL. The limits of quantification (LOQ) and detection (LOD) were 0.0068 and 0.0023 ng/mL, respectively. The relative standard deviation values for interday and intraday measurements of the standard solutions ranged from 0.24% to 3.76%. The mean recoveries for 0.240. in the tablet formulation were calculated as 98.0-99.9%. Conclusion: The developed method was used to determine the amount of rosuvastatin in tablets, and the results were compared with a 95% confidence level to those obtained using a literature method. The suggested approach works well for sensitive routine analysis and monitoring of drugs at low concentrations to investigate their bioavailability and bioequivalence.

Authors

Publication Details

Journal
Istanbul Journal of Pharmacy
Published
2024-12-30
DOI
https://doi.org/10.26650/istanbuljpharm.2024.1515450
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly sensitive carboxyl group fluorimetric derivatization HPLC analysis for rosuvastatin content in tablets

Sıdıka Ertürk Toker, Gamze Ergin Kızılçay, Elif Özdemir, Sena Çağlar-Andac
Istanbul Journal of Pharmacy
Analytical Methods in Pharmaceuticals
article

Highly sensitive carboxyl group fluorimetric derivatization HPLC analysis for rosuvastatin content in tablets

Sıdıka Ertürk Toker, Gamze Ergin Kızılçay, Elif Özdemir, Sena Çağlar-Andac
article en

Abstract

Background and Aims: The powerful antihyperlipidemic drug rosuvastatin blocks 3-hydroxy-3-methylglutaryl coenzyme A reductase, which is essential for cholesterol formation. Statins are a more recent class of antihyperlipidemic medications. Accurate quantification methods are crucial because of low rosuvastatin levels in tablets. The following the International Conference on Harmonisation (ICH) guidelines, a sensitive and high-performance liquid chromatographic approach was established in this study for the accurate determination of rosuvastatin in tablet formulations using spectrofluorimetric detection. Methods: The procedure requires one hour at room temperature and dark interaction between the acid group of rosuvastatin and the reagent 9-anthryldiazomethane. A C18 column (250 x 4.6 mm, 4 μm) was used for the gradient elution of an acetonitrile-water solution at a flow rate of 1.0 mL/min to achieve chromatographic separation. The internal reference was lovastatin. The excitation and emission wavelengths used for the detection were 366 and 410 nm, respectively. Results: Calibration curves for standard solutions were established by plotting the ratio of concentration to peak area over the range 0.01–20.0 ng/mL. The limits of quantification (LOQ) and detection (LOD) were 0.0068 and 0.0023 ng/mL, respectively. The relative standard deviation values for interday and intraday measurements of the standard solutions ranged from 0.24% to 3.76%. The mean recoveries for 0.240. in the tablet formulation were calculated as 98.0-99.9%. Conclusion: The developed method was used to determine the amount of rosuvastatin in tablets, and the results were compared with a 95% confidence level to those obtained using a literature method. The suggested approach works well for sensitive routine analysis and monitoring of drugs at low concentrations to investigate their bioavailability and bioequivalence.

Istanbul Journal of PharmacyVol. 54(3)
Openalex Percentile: Top 76%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Highly sensitive carboxyl group fluorimetric derivatization HPLC analysis for rosuvastatin content in tablets — Sıdıka Ertürk Toker, Gamze Ergin Kızılçay, et al. · Istanbul Journal of Pharmacy (2024) | TGRS Research Map | TGRS