Theoretical and experimental study on micron-sized SiC micro-abrasives regulating ultrasonic cavitation intensity

Ultrasonic cavitation technology has shown significant advantages across scientific and engineering fields, where cavitation intensity is critical to its performance. However, strategies for precisely regulating cavitation intensity remain underexplored. This study addresses this gap by introducing micron-sized silicon carbide (SiC) micro-abrasives into the medium to adjust cavitation intensity. A mathematical model was developed to predict the influence of micro-abrasives on cavitation by modifying nucleation rates, fluid viscosity, and pressure fluctuations. Experiments were conducted to evaluate the effects of ultrasonic frequency, micro-abrasive particle size, and mass fraction on cavitation intensity. Fluorescence analysis revealed that adding SiC micro-abrasives significantly enhanced fluorescence intensity, indicating increased cavitation. At ultrasonic frequencies of 20, 30, and 40 kHz, fluorescence intensities increased from 197.4, 142.2, and 99.2 to 248.3, 190.7, and 140.1, respectively, demonstrating that lower frequencies produce higher cavitation intensity. When adding SiC micro-abrasives with particle sizes of 6.5, 13.4, and 34.7 μm, fluorescence intensities were 190.7, 164.6, and 157.4, respectively, showing a negative correlation between particle size and cavitation intensity. As the mass fraction of SiC increased from 0.5 % to 15 %, fluorescence intensity initially surged, then slightly decreased and stabilized. At a 5 % mass fraction, the enhancement was optimal, with fluorescence intensity increasing from 142.2 to 284.9. The experimental results aligned well with the theoretical predictions, confirming the model's accuracy. This study underscores the effectiveness of SiC micro-abrasives in enhancing cavitation intensity, offering scalable insights for optimizing ultrasonic cavitation in industrial applications.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Published
2024-12-30
DOI
https://doi.org/10.1016/j.saa.2024.125686
Citations
4
Primary Topic
Advanced Machining and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Theoretical and experimental study on micron-sized SiC micro-abrasives regulating ultrasonic cavitation intensity

Shida Chuai, Linzheng Ye, Xijing Zhu, Wenlong Li et al.
4 citations
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Advanced Machining and Optimization Techniques
0.83
article

Theoretical and experimental study on micron-sized SiC micro-abrasives regulating ultrasonic cavitation intensity

Shida Chuai, Linzheng Ye, Xijing Zhu, Wenlong Li, Yao Liu, Boyang Lv, Huaye Kong, Zexiao Wang
article en
4 citations

Abstract

Ultrasonic cavitation technology has shown significant advantages across scientific and engineering fields, where cavitation intensity is critical to its performance. However, strategies for precisely regulating cavitation intensity remain underexplored. This study addresses this gap by introducing micron-sized silicon carbide (SiC) micro-abrasives into the medium to adjust cavitation intensity. A mathematical model was developed to predict the influence of micro-abrasives on cavitation by modifying nucleation rates, fluid viscosity, and pressure fluctuations. Experiments were conducted to evaluate the effects of ultrasonic frequency, micro-abrasive particle size, and mass fraction on cavitation intensity. Fluorescence analysis revealed that adding SiC micro-abrasives significantly enhanced fluorescence intensity, indicating increased cavitation. At ultrasonic frequencies of 20, 30, and 40 kHz, fluorescence intensities increased from 197.4, 142.2, and 99.2 to 248.3, 190.7, and 140.1, respectively, demonstrating that lower frequencies produce higher cavitation intensity. When adding SiC micro-abrasives with particle sizes of 6.5, 13.4, and 34.7 μm, fluorescence intensities were 190.7, 164.6, and 157.4, respectively, showing a negative correlation between particle size and cavitation intensity. As the mass fraction of SiC increased from 0.5 % to 15 %, fluorescence intensity initially surged, then slightly decreased and stabilized. At a 5 % mass fraction, the enhancement was optimal, with fluorescence intensity increasing from 142.2 to 284.9. The experimental results aligned well with the theoretical predictions, confirming the model's accuracy. This study underscores the effectiveness of SiC micro-abrasives in enhancing cavitation intensity, offering scalable insights for optimizing ultrasonic cavitation in industrial applications.

Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyVol. 330
North University of China (CN)
Climate action
Openalex Percentile: Top 26%
Advanced Machining and Optimization Techniques
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.