Subsurface investigation for pre-foundation study utilizing integrated geophysical and geotechnical methods, UNILORIN campus

This study involves subsurface investigation of a proposed site within senior staff quarters at the University of Ilorin campus utilizing the electrical resistivity technique, magnetic method and geotechnical analysis for the pre-foundation study. The land magnetic survey was acquired at 20 m spacing along seven traverses with the use of Geometrics G857 Proton Precession Magnetometer revealing the presence of concealed basement contact separating the biotite schist in the north from granite gneiss in the south. The Schlumberger configuration was used for the 1-D vertical electrical sounding (VES) technique, with the current electrode spacing (AB/2) varied between 1 and 100 m, which revealed three to four geo-electric layers which include lateritic/topsoil (93-3053Ωm, 0.3–2.5 m), clayey-sand (127-639Ωm, 1–13.2 m), weathered basement/sandy-clay (55-767Ωm, 3.6–33.3 m), and fresh basement (above 1000Ωm). WINRESIST and Surfer were used for the processing of resistivity data while Microsoft Excel was adopted for ground magnetic processing. However, the geotechnical analysis conducted on undisturbed samples picked at different depths from eight pits dug to a depth of 2.3 m revealed the following: bulk density (1.80 g/cm3-1.99 g/cm3), dry density (1.67 g/cm3-1.86 g/cm3) liquid limits (22.3%-34.1%), plastic limits (12.6%-19.8%), plasticity index (9.7%-14.3%) and cone penetration test (89.8 kN/m2-2110.3 kN/m2 at a depth of 0.1 m to 0.3 m), in which all these geotechnical analysis results classified the soil to be competent in variations and assess soil mechanical behaviour to support structural loads within study area. The integration of geophysical and geotechnical results revealed high topsoil resistivity correlates with high bearing capacity and is interpreted as thick and compacted lateritic materials. Highlights:

Authors

Institutions

Publication Details

Journal
Discover Geoscience
Published
2024-12-30
DOI
https://doi.org/10.1007/s44288-024-00103-4
Citations
8
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
4.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Subsurface investigation for pre-foundation study utilizing integrated geophysical and geotechnical methods, UNILORIN campus

Sodiq Bamidele Adam, Taofeeq Ayinde ISSA, Abdulhameed Kayode Oniyangi, Gabriel Efomeh Omolaiye
8 citations
Discover Geoscience
Geophysical and Geoelectrical Methods
4.28
article

Subsurface investigation for pre-foundation study utilizing integrated geophysical and geotechnical methods, UNILORIN campus

Sodiq Bamidele Adam, Taofeeq Ayinde ISSA, Abdulhameed Kayode Oniyangi, Gabriel Efomeh Omolaiye
article en
8 citations

Abstract

This study involves subsurface investigation of a proposed site within senior staff quarters at the University of Ilorin campus utilizing the electrical resistivity technique, magnetic method and geotechnical analysis for the pre-foundation study. The land magnetic survey was acquired at 20 m spacing along seven traverses with the use of Geometrics G857 Proton Precession Magnetometer revealing the presence of concealed basement contact separating the biotite schist in the north from granite gneiss in the south. The Schlumberger configuration was used for the 1-D vertical electrical sounding (VES) technique, with the current electrode spacing (AB/2) varied between 1 and 100 m, which revealed three to four geo-electric layers which include lateritic/topsoil (93-3053Ωm, 0.3–2.5 m), clayey-sand (127-639Ωm, 1–13.2 m), weathered basement/sandy-clay (55-767Ωm, 3.6–33.3 m), and fresh basement (above 1000Ωm). WINRESIST and Surfer were used for the processing of resistivity data while Microsoft Excel was adopted for ground magnetic processing. However, the geotechnical analysis conducted on undisturbed samples picked at different depths from eight pits dug to a depth of 2.3 m revealed the following: bulk density (1.80 g/cm3-1.99 g/cm3), dry density (1.67 g/cm3-1.86 g/cm3) liquid limits (22.3%-34.1%), plastic limits (12.6%-19.8%), plasticity index (9.7%-14.3%) and cone penetration test (89.8 kN/m2-2110.3 kN/m2 at a depth of 0.1 m to 0.3 m), in which all these geotechnical analysis results classified the soil to be competent in variations and assess soil mechanical behaviour to support structural loads within study area. The integration of geophysical and geotechnical results revealed high topsoil resistivity correlates with high bearing capacity and is interpreted as thick and compacted lateritic materials. Highlights:

Discover GeoscienceVol. 2(1)
University of Ilorin (NG), Kwara State University (NG)
Openalex Percentile: Top 5%
Geophysical and Geoelectrical Methods
4.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.