Measuring Residents' Competence in Chest Tube Insertion on Thiel-Embalmed Bodies
The rating scale in the Assessment for Competence in Chest Tube InsertiON tool has a robust validity argument for use on Thiel-embalmed bodies, allowing it to be used in simulation-based mastery learning curricula. In contrast, its error checklist has insufficient reliability and validity to be used for summative assessment.