Quantitative estimation & validation of paracetamol and lornoxicam by using hydrotropy solubilization phenomena

Drug analysis used organic solvents, which are more expensive, hazardous, and polluting the environment. In order to present a straightforward, accurate, innovative, safe, and precise approach for determining the amounts of Lornoxicam (LOX) and Paracetamol (PCM) in bulk and tablet Dosage forms, an appropriate substitute for using organic solvents would be a hydrotropic solution. In order to perform spectrophotometric analysis, Lornoxicam and Paracetamol, which are poorly soluble in water, were dissolved from the fine powder of their tablets using urea solution, a hydrotropic agent. The suggested techniques are the simultaneous equation method and absorbance ratio method and the. LOX and PCM have respective λmax of 384 and 244 nm. In 8M urea (a hydrotropic agent), the concentration ranges were 2-10μg/ml (r2=0.999) and 20-60μg/ml (r2=0.999), respectively. LOX and PCM both follow Beer's law. Precision, Accuracy, and additional statistical evaluation values were discovered to be in good agreement with the recommended values after the proposed procedures were validated in accordance with ICH criteria.

Authors

Publication Details

Journal
International Journal of Pharmaceutical Chemistry and Analysis
Published
2024-12-15
DOI
https://doi.org/10.18231/j.ijpca.2024.047
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative estimation & validation of paracetamol and lornoxicam by using hydrotropy solubilization phenomena

Pooja Rathore, Mukesh Kumar, Mo Rayyan, Mukesh Kumar Jaiswal et al.
International Journal of Pharmaceutical Chemistry and Analysis
Analytical Chemistry and Chromatography
article

Quantitative estimation & validation of paracetamol and lornoxicam by using hydrotropy solubilization phenomena

Pooja Rathore, Mukesh Kumar, Mo Rayyan, Mukesh Kumar Jaiswal, Mohini Godke, Mohammad Saklain
article en

Abstract

Drug analysis used organic solvents, which are more expensive, hazardous, and polluting the environment. In order to present a straightforward, accurate, innovative, safe, and precise approach for determining the amounts of Lornoxicam (LOX) and Paracetamol (PCM) in bulk and tablet Dosage forms, an appropriate substitute for using organic solvents would be a hydrotropic solution. In order to perform spectrophotometric analysis, Lornoxicam and Paracetamol, which are poorly soluble in water, were dissolved from the fine powder of their tablets using urea solution, a hydrotropic agent. The suggested techniques are the simultaneous equation method and absorbance ratio method and the. LOX and PCM have respective λmax of 384 and 244 nm. In 8M urea (a hydrotropic agent), the concentration ranges were 2-10μg/ml (r2=0.999) and 20-60μg/ml (r2=0.999), respectively. LOX and PCM both follow Beer's law. Precision, Accuracy, and additional statistical evaluation values were discovered to be in good agreement with the recommended values after the proposed procedures were validated in accordance with ICH criteria.

International Journal of Pharmaceutical Chemistry and AnalysisVol. 11(4)
Openalex Percentile: Top 81%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.