The behavior of secant pile wall embedded within soil by numerical analysis

Deep excavation projects in areas with high groundwater levels, such as industrial zones with large, heavy structures, present significant challenges. Secant piling techniques offer an effective solution for these conditions. These retaining walls are constructed by overlapping reinforced concrete and plain concrete piles to form a continuous barrier against soil and water ingress. This research investigates the effectiveness of secant pile walls as a deep excavation support system, focusing on the impact of various parameters on ground movement, analyzed using the DeepEX program. The case study centers on the Al Dawoodi/Al Mansur District in Baghdad, Iraq. Key factors examined include excavation depth, water level fluctuations, pile diameter, wall stiffness, soil properties, and the bonding between piles. The results revealed that lowering the groundwater level decreases the total lateral earth pressure while enhancing lateral resistance. For a constant excavation depth of 12.85 m, the total active stress at a depth of 9 m decreases as the water table level drops. When the water table is at -1.8 m, the total active stress is 92.952 kN/m²; at -3.5 m, it decreases to 87.837 kN/m²; and at -5.5 m, it further reduces to 82.016 kN/m². Additionally, deeper excavations result in greater horizontal displacement at the top of the wall. Increasing the pile diameter from 0.6 m to 1.2 m reduces lateral displacement from 0.503 m to 0.467 m but increases the bending moments from 832.56 kN.m/m to 1430.22 kN.m/m within the secant pile wall. Furthermore, the interlock ratio between the piles significantly influences wall performance. As this ratio increases, the bending moment also rises, with moment resistance increasing from 1134.72 kN.m/m to 1209.94 kN.m/m when the overlap distance grows from 5% to 30% of the pile diameter. The analysis also demonstrates that enhancing the strength of the secondary piles within the wall leads to higher bending moments, improving the wall's stability against excavation-induced stresses.

Authors

Institutions

Publication Details

Journal
Engineering and Technology Journal
Published
2024-12-30
DOI
https://doi.org/10.30684/etj.2024.153503.1818
Primary Topic
Geotechnical Engineering and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The behavior of secant pile wall embedded within soil by numerical analysis

Mahmood Mahmood, Mohammed F. Aswad, Ashraf Hussein
Engineering and Technology Journal
Geotechnical Engineering and Analysis
article

The behavior of secant pile wall embedded within soil by numerical analysis

Mahmood Mahmood, Mohammed F. Aswad, Ashraf Hussein
article en

Abstract

Deep excavation projects in areas with high groundwater levels, such as industrial zones with large, heavy structures, present significant challenges. Secant piling techniques offer an effective solution for these conditions. These retaining walls are constructed by overlapping reinforced concrete and plain concrete piles to form a continuous barrier against soil and water ingress. This research investigates the effectiveness of secant pile walls as a deep excavation support system, focusing on the impact of various parameters on ground movement, analyzed using the DeepEX program. The case study centers on the Al Dawoodi/Al Mansur District in Baghdad, Iraq. Key factors examined include excavation depth, water level fluctuations, pile diameter, wall stiffness, soil properties, and the bonding between piles. The results revealed that lowering the groundwater level decreases the total lateral earth pressure while enhancing lateral resistance. For a constant excavation depth of 12.85 m, the total active stress at a depth of 9 m decreases as the water table level drops. When the water table is at -1.8 m, the total active stress is 92.952 kN/m²; at -3.5 m, it decreases to 87.837 kN/m²; and at -5.5 m, it further reduces to 82.016 kN/m². Additionally, deeper excavations result in greater horizontal displacement at the top of the wall. Increasing the pile diameter from 0.6 m to 1.2 m reduces lateral displacement from 0.503 m to 0.467 m but increases the bending moments from 832.56 kN.m/m to 1430.22 kN.m/m within the secant pile wall. Furthermore, the interlock ratio between the piles significantly influences wall performance. As this ratio increases, the bending moment also rises, with moment resistance increasing from 1134.72 kN.m/m to 1209.94 kN.m/m when the overlap distance grows from 5% to 30% of the pile diameter. The analysis also demonstrates that enhancing the strength of the secondary piles within the wall leads to higher bending moments, improving the wall's stability against excavation-induced stresses.

Engineering and Technology JournalVol. 0(0)
University of Technology - Iraq (IQ)
Life in Land
Openalex Percentile: Top 70%
Geotechnical Engineering and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.