Precision Alignment of the CMS Electromagnetic Calorimeter

The electromagnetic calorimeter (ECAL) of the CMS detector is a homogenous, fine-grained detector made of scintillating lead-tungstate crystals. It was designed to provide excellent energy resolution for electrons and photons and was crucial in the discovery of the Higgs boson. The performance of ECAL is essential for CMS physics analyses. The precise alignment of ECAL is necessary to achieve the high-level position resolution required for photon and electron reconstruction in CMS and their identification. The position of each ECAL module is determined to an accuracy of 1 mm using photogrammetry measurements in CMS; however, the calorimeter is placed within a 4 Tesla superconducting solenoid and to the effect of its strong magnetic field can slightly displace it. Further alignment of ECAL with respect to the CMS Tracker is performed using a dedicated data analysis. This poster will describe the CMS ECAL alignment procedure, present the alignment accuracy reached at the LHC Run 3, and introduce the alignment process automation put in place.

Authors

Institutions

Publication Details

Published
2024-12-28
DOI
https://doi.org/10.22323/1.478.0287
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precision Alignment of the CMS Electromagnetic Calorimeter

A. Krishna, Cort Stewart Thoreson
Particle Detector Development and Performance
article

Precision Alignment of the CMS Electromagnetic Calorimeter

A. Krishna, Cort Stewart Thoreson
article en

Abstract

The electromagnetic calorimeter (ECAL) of the CMS detector is a homogenous, fine-grained detector made of scintillating lead-tungstate crystals. It was designed to provide excellent energy resolution for electrons and photons and was crucial in the discovery of the Higgs boson. The performance of ECAL is essential for CMS physics analyses. The precise alignment of ECAL is necessary to achieve the high-level position resolution required for photon and electron reconstruction in CMS and their identification. The position of each ECAL module is determined to an accuracy of 1 mm using photogrammetry measurements in CMS; however, the calorimeter is placed within a 4 Tesla superconducting solenoid and to the effect of its strong magnetic field can slightly displace it. Further alignment of ECAL with respect to the CMS Tracker is performed using a dedicated data analysis. This poster will describe the CMS ECAL alignment procedure, present the alignment accuracy reached at the LHC Run 3, and introduce the alignment process automation put in place.

Boston University (US), Northeastern University (US)
Affordable and clean energy
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.