The Impact of Humidity on High Temperature Corrosion of Ferritic‐Austenitic Model Alloys in the Presence of KCL

ABSTRACT This study investigates the impact of humidity on the corrosion behavior of an Fe–18Cr–12Ni alloy in environments containing KCl, as a deposit, and either laboratory air or at 560°C for exposure times up to 330 h. Corrosion characteristics were analyzed using scanning electron microscopy (SEM) and X‐ray diffraction (XRD) with subsequent Rietveld analysis to quantify the obtained reaction products. Samples exposed to lab air and KCl showed half the weight gain in humid air than in dry atmospheres ( at 30.00% 0.07% relative humidity (r.H.) vs. at 1.58% 0.09% r.H.). The surface porosity, as determined by image analysis of SEM surface images, was lower for the samples exposed to humid air compared to dry air (5.5% 2.1% vs. 11.0% 2.2%, respectively). In a SO 2 containing environment humidity decreased the scale thickness for deposit induced corrosion significantly by one order of magnitude, reflected by a low amount of oxide phases such as , and . This study shows that humidity present in a hot gas containing other corrosive species, such as SO 2 , can be beneficial for KCl deposit induced corrosion of stainless steels.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2024-12-29
DOI
https://doi.org/10.1002/maco.202414575
Primary Topic
High-Temperature Coating Behaviors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Humidity on High Temperature Corrosion of Ferritic‐Austenitic Model Alloys in the Presence of KCL

Phillip Kingsbery, Thilo John, Christiane Stephan‐Scherb
Materials and Corrosion
High-Temperature Coating Behaviors
article

The Impact of Humidity on High Temperature Corrosion of Ferritic‐Austenitic Model Alloys in the Presence of KCL

Phillip Kingsbery, Thilo John, Christiane Stephan‐Scherb
article en

Abstract

ABSTRACT This study investigates the impact of humidity on the corrosion behavior of an Fe–18Cr–12Ni alloy in environments containing KCl, as a deposit, and either laboratory air or at 560°C for exposure times up to 330 h. Corrosion characteristics were analyzed using scanning electron microscopy (SEM) and X‐ray diffraction (XRD) with subsequent Rietveld analysis to quantify the obtained reaction products. Samples exposed to lab air and KCl showed half the weight gain in humid air than in dry atmospheres ( at 30.00% 0.07% relative humidity (r.H.) vs. at 1.58% 0.09% r.H.). The surface porosity, as determined by image analysis of SEM surface images, was lower for the samples exposed to humid air compared to dry air (5.5% 2.1% vs. 11.0% 2.2%, respectively). In a SO 2 containing environment humidity decreased the scale thickness for deposit induced corrosion significantly by one order of magnitude, reflected by a low amount of oxide phases such as , and . This study shows that humidity present in a hot gas containing other corrosive species, such as SO 2 , can be beneficial for KCl deposit induced corrosion of stainless steels.

Materials and CorrosionVol. 76(4)
Martin Luther University Halle-Wittenberg (DE), Freie Universität Berlin (DE)
Deutsche Forschungsgemeinschaft, Helmholtz-Zentrum Berlin für Materialien und Energie
Openalex Percentile: Top 59%
High-Temperature Coating Behaviors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.