Development of a Simultaneous Analytical Method for Amines Corresponding to 10 Typical Nitrosamines

Regulatory authorities in various countries have successively issued notices and guidance to pharmaceutical manufacturers and distributors to evaluate the risk of contamination of nitrosamines in pharmaceutical products and to take appropriate measures. Analysis of nitrosamines in pharmaceutical products is not easy due to the large number of foreign substances, and the risk of contamination is determined by first conducting a desk investigation of the manufacturing process of the APIs or pharmaceutical products. However, a desk investigation may miss the risk since this method is not based on actual measurements. Therefore, in addition to conventional desk-based investigation, a new method is required to pick up risks that cannot be covered by a desk investigation. Nitrosamines are known to be formed by the reaction of amines with nitrosating agents such as nitrite. In the case of small alkyl nitrosamines such as NDMA and NDEA, the origin of the amines is mostly residual amines in the APIs. Residual amines in the APIs are a potential nitrosamine contamination risk, although the extent of that risk has rarely been reported. In this study, we developed and validated a simultaneous analytical method for amines corresponding to 10 typical small alkyl nitrosamines. Good linearity was obtained in the range of 0.003 to 10 μg/mL for MPA, 0.003 to 2 μg/mL for DIPA and DBA, 0.003 to 1 μg/mL for MeP, DEA, EIPA, and DPA, and 0.003 to 0.2 μg/mL for DMA, MOR, and MBA. The limits of quantitation and detection were 0.003 and 0.001-0.003 μg/mL, respectively. The recovery rates ranged from 70 to 130% for 121 APIs and were more than 40% for 83 APIs. Repeatability was also good, with %RSD < 15%. Although the correlation between the amount of amines detected in the APIs and the nitrosamines in the pharmaceutical products is under investigation, we expect that this analytical method will be used to determine the residual amine contents in APIs and contribute to the risk assessment of the nitrosamine contamination.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2024-12-30
DOI
https://doi.org/10.1021/acsomega.4c06293
Citations
2
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Simultaneous Analytical Method for Amines Corresponding to 10 Typical Nitrosamines

Osamu Uchikawa, Shohei Fukuda, Kanako Kondo, Takehiro Hoshiyama
2 citations
ACS Omega
Water Treatment and Disinfection
0.63
article

Development of a Simultaneous Analytical Method for Amines Corresponding to 10 Typical Nitrosamines

Osamu Uchikawa, Shohei Fukuda, Kanako Kondo, Takehiro Hoshiyama
article en
2 citations

Abstract

Regulatory authorities in various countries have successively issued notices and guidance to pharmaceutical manufacturers and distributors to evaluate the risk of contamination of nitrosamines in pharmaceutical products and to take appropriate measures. Analysis of nitrosamines in pharmaceutical products is not easy due to the large number of foreign substances, and the risk of contamination is determined by first conducting a desk investigation of the manufacturing process of the APIs or pharmaceutical products. However, a desk investigation may miss the risk since this method is not based on actual measurements. Therefore, in addition to conventional desk-based investigation, a new method is required to pick up risks that cannot be covered by a desk investigation. Nitrosamines are known to be formed by the reaction of amines with nitrosating agents such as nitrite. In the case of small alkyl nitrosamines such as NDMA and NDEA, the origin of the amines is mostly residual amines in the APIs. Residual amines in the APIs are a potential nitrosamine contamination risk, although the extent of that risk has rarely been reported. In this study, we developed and validated a simultaneous analytical method for amines corresponding to 10 typical small alkyl nitrosamines. Good linearity was obtained in the range of 0.003 to 10 μg/mL for MPA, 0.003 to 2 μg/mL for DIPA and DBA, 0.003 to 1 μg/mL for MeP, DEA, EIPA, and DPA, and 0.003 to 0.2 μg/mL for DMA, MOR, and MBA. The limits of quantitation and detection were 0.003 and 0.001-0.003 μg/mL, respectively. The recovery rates ranged from 70 to 130% for 121 APIs and were more than 40% for 83 APIs. Repeatability was also good, with %RSD < 15%. Although the correlation between the amount of amines detected in the APIs and the nitrosamines in the pharmaceutical products is under investigation, we expect that this analytical method will be used to determine the residual amine contents in APIs and contribute to the risk assessment of the nitrosamine contamination.

ACS OmegaVol. 10(1)
Towa Pharmaceutical (Japan) (JP)
Partnerships for the goals
Openalex Percentile: Top 28%
Water Treatment and Disinfection
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of a Simultaneous Analytical Method for Amines Corresponding to 10 Typical Nitrosamines — Osamu Uchikawa, Shohei Fukuda, et al. · ACS Omega (2024) | TGRS Research Map | TGRS