INVESTIGATION OF TRANSIENTS IN GROUNDING GRIDS

he grounding grid of a power system is very important for absorbing the harmful overvoltages and/or overcurrents during transients. The lightning surges frequently causes overvoltages and/or overcur- rents via the grounding grid. This may have dangerous effects on persons and/or equipment. Therefore, this paper reviews in detail the transient in grounding grids due to lightning surges. The grounding grid configura- tions and mathematical modeling are explained. Many configurations are used in the analysis such as one, four, sixteen meshes grounding configurations. Also, two injection points are analyzed: at the terminal and the middle of the grid. The analysis is carried out using ATP/EMTP. Many transient responses of voltages and currents at different points of the grounding grid for different configurations are calculated and compared. The peak voltage and current values are compared to be the basis of safety design of the grounding system.

Authors

Publication Details

Journal
Advances in Electrical and Electronic Engineering
Published
2024-12-30
DOI
https://doi.org/10.15598/aeee.v22i4.240412
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INVESTIGATION OF TRANSIENTS IN GROUNDING GRIDS

Ibrahim Mansy, Ebrahim A. Badran, Basma M. Samy
Advances in Electrical and Electronic Engineering
Electrical Fault Detection and Protection
article

INVESTIGATION OF TRANSIENTS IN GROUNDING GRIDS

Ibrahim Mansy, Ebrahim A. Badran, Basma M. Samy
article en

Abstract

he grounding grid of a power system is very important for absorbing the harmful overvoltages and/or overcurrents during transients. The lightning surges frequently causes overvoltages and/or overcur- rents via the grounding grid. This may have dangerous effects on persons and/or equipment. Therefore, this paper reviews in detail the transient in grounding grids due to lightning surges. The grounding grid configura- tions and mathematical modeling are explained. Many configurations are used in the analysis such as one, four, sixteen meshes grounding configurations. Also, two injection points are analyzed: at the terminal and the middle of the grid. The analysis is carried out using ATP/EMTP. Many transient responses of voltages and currents at different points of the grounding grid for different configurations are calculated and compared. The peak voltage and current values are compared to be the basis of safety design of the grounding system.

Advances in Electrical and Electronic EngineeringVol. 22(4)
Climate action
Openalex Percentile: Top 78%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.