Experimental Study on the Fire Impact of Ceiling Insulation on CPVC Pipes

Fires igniting within a ceiling space often escalate into large-scale fires because of delayed detection times, rapid fire spread, and difficulties in firefighting operations. This study investigated the effect of combustible insulation materials on CPVC piping in sprinkler systems using real-scale fire experiments. Based on the top floor of an apartment, this study focused on insulation materials with the highest fire load among the combustibles in the ceiling space. A field survey and fire tests were conducted, and the experiments with EPS and XPS insulation revealed rapid flame spread and the complete destruction of the CPVC piping owing to high heat intensity. Even PIR insulation, a fire-resistant material, causes the destruction of CPVC piping located directly above the fire source. This confirms that combustible insulation materials within the ceiling have a significant negative impact on the functionality of the CPVC piping, rendering it incapable of performing its intended functions. Therefore, this study suggests alternatives for enhancing the reliability of automatic fire-suppression systems during fires in ceiling spaces.

Authors

Publication Details

Journal
Korean Society of Hazard Mitigation
Published
2024-12-29
DOI
https://doi.org/10.9798/kosham.2024.24.6.203
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on the Fire Impact of Ceiling Insulation on CPVC Pipes

Heung Yeol Kim, Eun Young Lee
Korean Society of Hazard Mitigation
Fire dynamics and safety research
article

Experimental Study on the Fire Impact of Ceiling Insulation on CPVC Pipes

Heung Yeol Kim, Eun Young Lee
article en

Abstract

Fires igniting within a ceiling space often escalate into large-scale fires because of delayed detection times, rapid fire spread, and difficulties in firefighting operations. This study investigated the effect of combustible insulation materials on CPVC piping in sprinkler systems using real-scale fire experiments. Based on the top floor of an apartment, this study focused on insulation materials with the highest fire load among the combustibles in the ceiling space. A field survey and fire tests were conducted, and the experiments with EPS and XPS insulation revealed rapid flame spread and the complete destruction of the CPVC piping owing to high heat intensity. Even PIR insulation, a fire-resistant material, causes the destruction of CPVC piping located directly above the fire source. This confirms that combustible insulation materials within the ceiling have a significant negative impact on the functionality of the CPVC piping, rendering it incapable of performing its intended functions. Therefore, this study suggests alternatives for enhancing the reliability of automatic fire-suppression systems during fires in ceiling spaces.

Korean Society of Hazard MitigationVol. 24(6)
Sustainable cities and communities
Openalex Percentile: Top 70%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.