Towards in-line rheology measurement of protein melts during high moisture extrusion by pulsed ultrasound velocimetry

The present paper is concerned with the development of a custom pulsed ultrasound velocity profiling (PUV) methodology to non-invasively measure, analyze and control protein melt flow and power-law flow indices in the cooling die during high moisture (HME) extrusion processing. The methodology is first validated on glycerol and a carboxymethyl cellulose (CMC) solution as Newtonian and shear-thinning reference fluids, respectively, at different flow rates followed by application to two pea protein melts at different moisture contents (MCs) in the low flow rate regime typical of a pilot-scale extruder and characterized by a poor signal to noise ratio (SNR) close to the extruder die wall. The flow indices were compared with those obtained from conventional rheometry, showing good agreement for the reference fluids and semi-quantitative agreement for the protein melts. The study confirms that PUV can be used for in-line application in a cooling die by measuring the local flow conditions, as well as contribute to the understanding of protein melt fibre formation. On the other hand, the SNR close to the die wall need to be improved e.g. by using an ultrasound transducer operating at higher frequency and modifying the die to enable quantitative agreement with flow simulations to properly extract local rheometric data. Thus, it is concluded that further refinement of the methodology is both possible and needed to improve the accuracy of the measurements in future work for in-line application during HME extrusion. • In-line rheometry of protein melts using the PUV method is possible. • Good agreement with conventional rheometry for reference fluids. • Semi-quantitative agreement with conventional rheometry for protein melts. • PUV can estimate local rheometry in the cooling die. • The method may contribute to the understanding of protein melt fibre formation.

Authors

Institutions

Publication Details

Journal
Journal of Food Engineering
Published
2024-12-29
DOI
https://doi.org/10.1016/j.jfoodeng.2024.112461
Citations
3
Primary Topic
Material Properties and Processing
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards in-line rheology measurement of protein melts during high moisture extrusion by pulsed ultrasound velocimetry

Reinhardt Kotzé, Erik Kaunisto, Bahiru Tsegaye, Mats Stading et al.
3 citations
Journal of Food Engineering
Material Properties and Processing
0.81
article

Towards in-line rheology measurement of protein melts during high moisture extrusion by pulsed ultrasound velocimetry

Reinhardt Kotzé, Erik Kaunisto, Bahiru Tsegaye, Mats Stading, Roland Kádár, Johan Wiklund
article en
3 citations

Abstract

The present paper is concerned with the development of a custom pulsed ultrasound velocity profiling (PUV) methodology to non-invasively measure, analyze and control protein melt flow and power-law flow indices in the cooling die during high moisture (HME) extrusion processing. The methodology is first validated on glycerol and a carboxymethyl cellulose (CMC) solution as Newtonian and shear-thinning reference fluids, respectively, at different flow rates followed by application to two pea protein melts at different moisture contents (MCs) in the low flow rate regime typical of a pilot-scale extruder and characterized by a poor signal to noise ratio (SNR) close to the extruder die wall. The flow indices were compared with those obtained from conventional rheometry, showing good agreement for the reference fluids and semi-quantitative agreement for the protein melts. The study confirms that PUV can be used for in-line application in a cooling die by measuring the local flow conditions, as well as contribute to the understanding of protein melt fibre formation. On the other hand, the SNR close to the die wall need to be improved e.g. by using an ultrasound transducer operating at higher frequency and modifying the die to enable quantitative agreement with flow simulations to properly extract local rheometric data. Thus, it is concluded that further refinement of the methodology is both possible and needed to improve the accuracy of the measurements in future work for in-line application during HME extrusion. • In-line rheometry of protein melts using the PUV method is possible. • Good agreement with conventional rheometry for reference fluids. • Semi-quantitative agreement with conventional rheometry for protein melts. • PUV can estimate local rheometry in the cooling die. • The method may contribute to the understanding of protein melt fibre formation.

Journal of Food EngineeringVol. 391
RISE Research Institutes of Sweden (SE), Frölunda Specialist Hospital (SE), Chalmers University of Technology (SE)
Svenska Forskningsrådet Formas
Zero hunger
Openalex Percentile: Top 31%
Material Properties and Processing
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.