Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite

Abstract FengYun‐3E (FY‐3E) was the first operational meteorological satellite in China in early morning orbit. The radiation dosimeter, which is part of the satellite's Space Environment Monitor (SEM), contains three probes to measure the total ionizing dose in the three directions of the satellite. Improvements in the dosimeter have been made to increase detection sensitivity. The RADFET, a radiation dose sensor, was calibrated using 60 Co radionuclide source to correlate its threshold voltage shift with the total ionizing dose. The improved dosimeter has a sensitivity of 0.06 rad (Si) to 0.45 rad (Si) in the measurement range. The flight data showed that the total ionizing dose within the FY‐3E satellite is anisotropic. The radiation dose rate in the +X and +Y directions increased by a few factors after the geomagnetic storms.

Authors

Institutions

Publication Details

Journal
Journal of Geophysical Research Space Physics
Published
2024-12-29
DOI
https://doi.org/10.1029/2024ja033016
Citations
2
Primary Topic
Ionosphere and magnetosphere dynamics
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite

Jing‐Tao Lü, Binquan Zhang, Zheng Chang, Yanli Sun et al.
2 citations
Journal of Geophysical Research Space Physics
Ionosphere and magnetosphere dynamics
0.66
article

Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite

Jing‐Tao Lü, Binquan Zhang, Zheng Chang, Yanli Sun, Guanghui Shen, Yu‐Ting Chang, Chi Wang, Peng Zhang, Xiaoguang Zhang, Cong Huang
article en
2 citations

Abstract

Abstract FengYun‐3E (FY‐3E) was the first operational meteorological satellite in China in early morning orbit. The radiation dosimeter, which is part of the satellite's Space Environment Monitor (SEM), contains three probes to measure the total ionizing dose in the three directions of the satellite. Improvements in the dosimeter have been made to increase detection sensitivity. The RADFET, a radiation dose sensor, was calibrated using 60 Co radionuclide source to correlate its threshold voltage shift with the total ionizing dose. The improved dosimeter has a sensitivity of 0.06 rad (Si) to 0.45 rad (Si) in the measurement range. The flight data showed that the total ionizing dose within the FY‐3E satellite is anisotropic. The radiation dose rate in the +X and +Y directions increased by a few factors after the geomagnetic storms.

Journal of Geophysical Research Space PhysicsVol. 130(1)
Chinese Academy of Sciences (CN), Shanghai Micro Satellite Engineering Center (CN), National Space Science Center (CN), Space Engineering University (CN)
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
Life below water
Openalex Percentile: Top 26%
Ionosphere and magnetosphere dynamics
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.