Compensating elastic faults in a torque-assisted knee exoskeleton: functional evaluation and user perception study

Wearable robots are often powered by elastic actuators, which can mimic the intrinsic compliance observed in human joints, contributing to safe and seamless interaction. However, due to their increased complexity, when compared to direct drives, elastic actuators are susceptible to faults, which pose significant challenges, potentially compromising user experience and safety during interaction. In this article, we developed a fault-tolerant control strategy for torque assistance in a knee exoskeleton and investigated user experience during a walking task while emulating faults. We implemented and evaluated the torque control scheme, based on impedance control, for a mechanically adjustable compliance actuator with nonlinear torque-deflection characteristics. Conducted functional evaluation experiments showed that the control strategy is capable of providing support during gait based on a torque profile. A user study was conducted to evaluate the impact of fault severity and compensation on the perception of support, stiffness, comfort, and trust while walking with the exoskeleton. Results from the user study revealed significant differences in participants' responses when comparing support and stiffness levels without fault compensation. In contrast, no significant differences were found when faults were compensated, indicating that fault tolerance can be achieved in practice. Meanwhile, comfort and trust measurements do not seem to depend directly on torque support levels, pointing to other influencing factors that could be considered in future research.

Authors

Institutions

Publication Details

Journal
Journal of NeuroEngineering and Rehabilitation
Published
2024-12-28
DOI
https://doi.org/10.1186/s12984-024-01531-6
Citations
3
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compensating elastic faults in a torque-assisted knee exoskeleton: functional evaluation and user perception study

Adna Bliek, Bram Vanderborght, Rodrigo J. Velasco-Guillen, Josep M. Font-Llagunes et al.
3 citations
Journal of NeuroEngineering and Rehabilitation
Prosthetics and Rehabilitation Robotics
0.55
article

Compensating elastic faults in a torque-assisted knee exoskeleton: functional evaluation and user perception study

Adna Bliek, Bram Vanderborght, Rodrigo J. Velasco-Guillen, Josep M. Font-Llagunes, Philipp Beckerle
article en
3 citations

Abstract

Wearable robots are often powered by elastic actuators, which can mimic the intrinsic compliance observed in human joints, contributing to safe and seamless interaction. However, due to their increased complexity, when compared to direct drives, elastic actuators are susceptible to faults, which pose significant challenges, potentially compromising user experience and safety during interaction. In this article, we developed a fault-tolerant control strategy for torque assistance in a knee exoskeleton and investigated user experience during a walking task while emulating faults. We implemented and evaluated the torque control scheme, based on impedance control, for a mechanically adjustable compliance actuator with nonlinear torque-deflection characteristics. Conducted functional evaluation experiments showed that the control strategy is capable of providing support during gait based on a torque profile. A user study was conducted to evaluate the impact of fault severity and compensation on the perception of support, stiffness, comfort, and trust while walking with the exoskeleton. Results from the user study revealed significant differences in participants' responses when comparing support and stiffness levels without fault compensation. In contrast, no significant differences were found when faults were compensated, indicating that fault tolerance can be achieved in practice. Meanwhile, comfort and trust measurements do not seem to depend directly on torque support levels, pointing to other influencing factors that could be considered in future research.

Journal of NeuroEngineering and RehabilitationVol. 21(1)
Vrije Universiteit Brussel (BE), Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), IMEC (BE), Sant Joan de Déu Research Foundation (ES), Institut de Recerca Sant Joan de Déu, Universitat Politècnica de Catalunya (ES)
Friedrich-Alexander-Universität Erlangen-Nürnberg, Deutsche Forschungsgemeinschaft
Life below water
Openalex Percentile: Top 35%
Prosthetics and Rehabilitation Robotics
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.