Retention mechanism on phosphodiester stationary phases in HILIC and purely aqueous mobile phase, Part I: The problem of hold-up volume determination

Non-destructive chromatographic methods were used to determine the hold-up volumes of four self-packed columns containing embedded phosphate groups. The stationary phases are named Diol-P-C10, Diol-P-C18, Diol-P-Benzyl and Diol-P-Chol. The hydrophobicity of organic ligands bound to the phosphate group increases in the benzyl< decyl < octadecyl <cholesterol direction. Using a stochastic model of inverse size exclusion chromatography with a wide pore size distribution, the hold-up volume, interstitial volume and pore volume of the columns were determined. Using the method of minor disturbances, the thermodynamic hold-up volume of the columns was calculated and the excess isotherm was determined for acetonitrile-water mobile phases. The results show that these stationary phases can be used effectively in RPLC and HILIC. When using hold-up volume markers, it was found that the composition of the mobile phase has to be taken into account. In the case of protic solvents, inorganic salts are excluded from the pores and their elution volume is not the total hold-up volume. Rather, in the case of aprotic mobile phase, retention occurs due to the adsorbed water layer.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2024-12-28
DOI
https://doi.org/10.1016/j.chroma.2024.465627
Citations
3
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retention mechanism on phosphodiester stationary phases in HILIC and purely aqueous mobile phase, Part I: The problem of hold-up volume determination

Alessandro Buratti, Martina Catani, Mikołaj Dembek, Attila Felinger et al.
3 citations
Journal of Chromatography A
Analytical Chemistry and Chromatography
0.72
article

Retention mechanism on phosphodiester stationary phases in HILIC and purely aqueous mobile phase, Part I: The problem of hold-up volume determination

Alessandro Buratti, Martina Catani, Mikołaj Dembek, Attila Felinger, Szymon Bocian, Ivett Bacskay, Bogusław Buszewski
article en
3 citations

Abstract

Non-destructive chromatographic methods were used to determine the hold-up volumes of four self-packed columns containing embedded phosphate groups. The stationary phases are named Diol-P-C10, Diol-P-C18, Diol-P-Benzyl and Diol-P-Chol. The hydrophobicity of organic ligands bound to the phosphate group increases in the benzyl< decyl < octadecyl <cholesterol direction. Using a stochastic model of inverse size exclusion chromatography with a wide pore size distribution, the hold-up volume, interstitial volume and pore volume of the columns were determined. Using the method of minor disturbances, the thermodynamic hold-up volume of the columns was calculated and the excess isotherm was determined for acetonitrile-water mobile phases. The results show that these stationary phases can be used effectively in RPLC and HILIC. When using hold-up volume markers, it was found that the composition of the mobile phase has to be taken into account. In the case of protic solvents, inorganic salts are excluded from the pores and their elution volume is not the total hold-up volume. Rather, in the case of aprotic mobile phase, retention occurs due to the adsorbed water layer.

Journal of Chromatography AVol. 1742
University of Ferrara (IT), Nicolaus Copernicus University (PL), University of Pecs (HU)
Clean water and sanitation
Openalex Percentile: Top 31%
Analytical Chemistry and Chromatography
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retention mechanism on phosphodiester stationary phases in HILIC and purely aqueous mobile phase, Part I: The problem of hold-up volume determination — Alessandro Buratti, Martina Catani, et al. · Journal of Chromatography A (2024) | TGRS Research Map | TGRS