Impact of Pre-Exchanging Anion-Exchange Polymer for Water Electrolysis and Fuel Cell Applications

Pretreatment of anion-exchange membranes (AEMs) prior to their use in AEM fuel cells (AEMFCs) and AEM water electrolyzers (AEMWEs) is typically required to replace the anions with hydroxide (OH–). Herein, hexamethyl-p-terphenyl poly(benzimidazolium) iodide (HMT-PMBI) (I–) was used as a model AEM to investigate the exchange process. The exchanging solution (containing I–, released from AEMs) was first examined by silver ions, where we found that no more precipitates can be visually observed after 3 exchanges. Moreover, we developed a quantitative method based on UV–vis spectroscopy, which is able to show that ∼61, 84, and 87% of the original I– was removed after 1, 2, and 3 exchanges in 3 M KOH. In operando electrochemical studies revealed that current–voltage characteristics of AEMFCs are sensitive to residual iodide within the membrane, requiring at least three exchange cycles (>90% removal of iodide) to reach maximum performance. In contrast, AEMWEs are less sensitive to the exchange process, with trace iodide being effectively flushed during electrolysis.

Authors

Institutions

Publication Details

Journal
ACS Applied Polymer Materials
Published
2024-12-28
DOI
https://doi.org/10.1021/acsapm.4c03115
Citations
2
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Pre-Exchanging Anion-Exchange Polymer for Water Electrolysis and Fuel Cell Applications

Qiliang Wei, Binyu Chen, Steven Holdcroft, Alessandra S. Menandro
2 citations
ACS Applied Polymer Materials
Fuel Cells and Related Materials
0.42
article

Impact of Pre-Exchanging Anion-Exchange Polymer for Water Electrolysis and Fuel Cell Applications

Qiliang Wei, Binyu Chen, Steven Holdcroft, Alessandra S. Menandro
article en
2 citations

Abstract

Pretreatment of anion-exchange membranes (AEMs) prior to their use in AEM fuel cells (AEMFCs) and AEM water electrolyzers (AEMWEs) is typically required to replace the anions with hydroxide (OH–). Herein, hexamethyl-p-terphenyl poly(benzimidazolium) iodide (HMT-PMBI) (I–) was used as a model AEM to investigate the exchange process. The exchanging solution (containing I–, released from AEMs) was first examined by silver ions, where we found that no more precipitates can be visually observed after 3 exchanges. Moreover, we developed a quantitative method based on UV–vis spectroscopy, which is able to show that ∼61, 84, and 87% of the original I– was removed after 1, 2, and 3 exchanges in 3 M KOH. In operando electrochemical studies revealed that current–voltage characteristics of AEMFCs are sensitive to residual iodide within the membrane, requiring at least three exchange cycles (>90% removal of iodide) to reach maximum performance. In contrast, AEMWEs are less sensitive to the exchange process, with trace iodide being effectively flushed during electrolysis.

ACS Applied Polymer MaterialsVol. 7(1)
Simon Fraser University (CA)
Natural Sciences and Engineering Research Council of Canada
Clean water and sanitation
Openalex Percentile: Top 36%
Fuel Cells and Related Materials
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of Pre-Exchanging Anion-Exchange Polymer for Water Electrolysis and Fuel Cell Applications — Qiliang Wei, Binyu Chen, et al. · ACS Applied Polymer Materials (2024) | TGRS Research Map | TGRS