A comparative numerical study of various ribs geometries on the performance of a solar air heater absorber plate

Abstract In this study, a numerical investigation is conducted to compare the impact of various ribs such as transverse, inclined, V-shaped and arc-shaped fixed on the absorber plate of a solar air heater under consistent boundary conditions. The analysis considers Reynolds numbers ranging from 3000 to 15000 and a heat flux corresponding to 1000 W m −2 . Various geometric characteristics of the ribs, including relative roughness height, relative pitch, number of gaps, rib-arm angle (attack angle), and relative gap width, are kept constant throughout the investigation in this comparative analysis. The simulations are carried out using ANSYS-Fluent software, and the theoretical results are employed for validation. Results indicate that at Reynolds number 15,000, the maximum Thermal-Hydraulic Performance Parameter (THPP) for V-shaped ribs is 2.15 followed by arc-shaped ribs as 1.6.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2024-12-27
DOI
https://doi.org/10.1088/2631-8695/ada3b0
Citations
1
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparative numerical study of various ribs geometries on the performance of a solar air heater absorber plate

Dinesh Kumar Sharma, Rahul Goyal, Hemant Singh, Ankur Srivastava
1 citations
Engineering Research Express
Heat Transfer Mechanisms
0.21
article

A comparative numerical study of various ribs geometries on the performance of a solar air heater absorber plate

Dinesh Kumar Sharma, Rahul Goyal, Hemant Singh, Ankur Srivastava
article en
1 citations

Abstract

Abstract In this study, a numerical investigation is conducted to compare the impact of various ribs such as transverse, inclined, V-shaped and arc-shaped fixed on the absorber plate of a solar air heater under consistent boundary conditions. The analysis considers Reynolds numbers ranging from 3000 to 15000 and a heat flux corresponding to 1000 W m −2 . Various geometric characteristics of the ribs, including relative roughness height, relative pitch, number of gaps, rib-arm angle (attack angle), and relative gap width, are kept constant throughout the investigation in this comparative analysis. The simulations are carried out using ANSYS-Fluent software, and the theoretical results are employed for validation. Results indicate that at Reynolds number 15,000, the maximum Thermal-Hydraulic Performance Parameter (THPP) for V-shaped ribs is 2.15 followed by arc-shaped ribs as 1.6.

Engineering Research ExpressVol. 7(1)
Institute of Technology Management (IN), Manipal University Jaipur
Affordable and clean energy
Openalex Percentile: Top 48%
Heat Transfer Mechanisms
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A comparative numerical study of various ribs geometries on the performance of a solar air heater absorber plate — Dinesh Kumar Sharma, Rahul Goyal, et al. · Engineering Research Express (2024) | TGRS Research Map | TGRS