Enhanced high-sensitivity multi-layer neutron detector based on LiF:ZnS(Ag) scintillator

This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors. The research focused on optimizing a single layer for maximum sensitivity and proper gamma rejection capabilities. This optimized configuration is then replicated to form the multi-layer detector. A primary challenge with the LiF:ZnS(Ag) scintillator is its inherent opacity, limiting its width and consequently, its detection efficiency. Our proposed multi-layer structure addresses this limitation by employing a thin scintillator in each layer. This strategic design minimizes emitted light attenuation while simultaneously enhancing sensitivity through the cumulative effect of multiple layers. Our experiments demonstrate a significant improvement in detection efficiency compared to the single-layer setup. Additionally, our architecture offers an actual improvement in differentiating between gamma and neutron signals. By analyzing count rates across the detector's layers, we gain valuable operational insights, such as the ability to predict the source direction. Our finding demonstrates an improved sensitivity achieved by minimal loss of neutrons during the moderation of 329% compared to a single layer, aligned with the potential range of improvement while maintaining extremely high gamma rejection. Supported by the presented findings, this design represents a noticeable advancement over existing solutions, offering scalable customization to user requirements. Notably, it outperforms traditional <sup>3</sup>He tube-based detection configurations, positioning it as a compelling and advantageous replacement option.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-12-28
DOI
https://doi.org/10.1038/s41598-024-83129-5
Citations
3
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced high-sensitivity multi-layer neutron detector based on LiF:ZnS(Ag) scintillator

Itzhak Orion, A. Osovizky, Ilan Cohen Zada
3 citations
Scientific Reports
Radiation Detection and Scintillator Technologies
1.82
article

Enhanced high-sensitivity multi-layer neutron detector based on LiF:ZnS(Ag) scintillator

Itzhak Orion, A. Osovizky, Ilan Cohen Zada
article en
3 citations

Abstract

This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors. The research focused on optimizing a single layer for maximum sensitivity and proper gamma rejection capabilities. This optimized configuration is then replicated to form the multi-layer detector. A primary challenge with the LiF:ZnS(Ag) scintillator is its inherent opacity, limiting its width and consequently, its detection efficiency. Our proposed multi-layer structure addresses this limitation by employing a thin scintillator in each layer. This strategic design minimizes emitted light attenuation while simultaneously enhancing sensitivity through the cumulative effect of multiple layers. Our experiments demonstrate a significant improvement in detection efficiency compared to the single-layer setup. Additionally, our architecture offers an actual improvement in differentiating between gamma and neutron signals. By analyzing count rates across the detector's layers, we gain valuable operational insights, such as the ability to predict the source direction. Our finding demonstrates an improved sensitivity achieved by minimal loss of neutrons during the moderation of 329% compared to a single layer, aligned with the potential range of improvement while maintaining extremely high gamma rejection. Supported by the presented findings, this design represents a noticeable advancement over existing solutions, offering scalable customization to user requirements. Notably, it outperforms traditional <sup>3</sup>He tube-based detection configurations, positioning it as a compelling and advantageous replacement option.

Scientific ReportsVol. 14(1)
Ben-Gurion University of the Negev (IL), Israel Aerospace Industries (Israel) (IL), General Electric (Israel) (IL)
Affordable and clean energy
Openalex Percentile: Top 14%
Radiation Detection and Scintillator Technologies
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.