Impact of Thermal Aging on Marginal Adaptation in Lithium Disilicate CAD/CAM Crowns with Deep Proximal Box Elevation

BACKGROUND This computer-aided design and computer-aided manufacturing (CAD/CAM) study aimed to evaluate the effects of thermocycling on deep margin elevation relocation of subgingival cavity outlines in 80 molar teeth using advanced lithium disilicate ceramic. MATERIAL AND METHODS Eighty mandibular molar teeth were prepared for deep margin elevation below the cementoenamel junction. The following types of restorations were subsequently applied to each group: glass ionomer filling, bulk-fill flowable resin composite, bioactive resin composite, and nanohybrid resin composite. Full-coverage crowns with standardized preparation and a shoulder finish line were prepared to receive CAD/CAM-milled advanced lithium disilicate crowns. Samples were examined at 6 equidistant points via digital microscope on each proximal surface at the restoration-tooth and crown-restoration interfaces before and after thermocycling for 15 000 cycles. Data were analyzed using one-way analysis of variance, at a level of significance of 0.05. RESULTS The vertical marginal gap was significantly higher after aging and was the highest for glass ionomer filling, 9.091 (±1.147) and 9.936 (±6.376) µm, followed by nanohybrid resin composite, 3.59 (±1.03) and 3.87 (±0.97) µm, bioactive resin composite, 3.17 (±0.81) and 2.59 (±0.21) µm, and bulk-fill flowable resin composite, 1.89 (±0.60) and 2.42 (±0.64) µm, at the cervical and apical interfaces, respectively. CONCLUSIONS Thermocycling significantly changed the marginal adaptation of all restorative materials. Highest values for marginal adaptation were recorded in the glass ionomer filling group, followed by nanohybrid composite and bioactive resin groups, whereas lowest values were recorded among the bulk-fill flowable resin composite group at cervical and apical interfaces.

Authors

Institutions

Publication Details

Journal
Medical Science Monitor
Published
2024-12-21
DOI
https://doi.org/10.12659/msm.947191
Citations
3
Primary Topic
Additive Manufacturing and 3D Printing Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Thermal Aging on Marginal Adaptation in Lithium Disilicate CAD/CAM Crowns with Deep Proximal Box Elevation

Mohammed M. Al Moaleem, Waad Khayat, Heba Mitwalli, Nassreen H. Albar et al.
3 citations
Medical Science Monitor
Additive Manufacturing and 3D Printing Technologies
0.61
article

Impact of Thermal Aging on Marginal Adaptation in Lithium Disilicate CAD/CAM Crowns with Deep Proximal Box Elevation

Mohammed M. Al Moaleem, Waad Khayat, Heba Mitwalli, Nassreen H. Albar, Arwa Daghrery, Bashayer H. Baras, Maysaa Z. Khojah, Eman Jabarti
article en
3 citations

Abstract

BACKGROUND This computer-aided design and computer-aided manufacturing (CAD/CAM) study aimed to evaluate the effects of thermocycling on deep margin elevation relocation of subgingival cavity outlines in 80 molar teeth using advanced lithium disilicate ceramic. MATERIAL AND METHODS Eighty mandibular molar teeth were prepared for deep margin elevation below the cementoenamel junction. The following types of restorations were subsequently applied to each group: glass ionomer filling, bulk-fill flowable resin composite, bioactive resin composite, and nanohybrid resin composite. Full-coverage crowns with standardized preparation and a shoulder finish line were prepared to receive CAD/CAM-milled advanced lithium disilicate crowns. Samples were examined at 6 equidistant points via digital microscope on each proximal surface at the restoration-tooth and crown-restoration interfaces before and after thermocycling for 15 000 cycles. Data were analyzed using one-way analysis of variance, at a level of significance of 0.05. RESULTS The vertical marginal gap was significantly higher after aging and was the highest for glass ionomer filling, 9.091 (±1.147) and 9.936 (±6.376) µm, followed by nanohybrid resin composite, 3.59 (±1.03) and 3.87 (±0.97) µm, bioactive resin composite, 3.17 (±0.81) and 2.59 (±0.21) µm, and bulk-fill flowable resin composite, 1.89 (±0.60) and 2.42 (±0.64) µm, at the cervical and apical interfaces, respectively. CONCLUSIONS Thermocycling significantly changed the marginal adaptation of all restorative materials. Highest values for marginal adaptation were recorded in the glass ionomer filling group, followed by nanohybrid composite and bioactive resin groups, whereas lowest values were recorded among the bulk-fill flowable resin composite group at cervical and apical interfaces.

Medical Science MonitorVol. 31
Umm al-Qura University (SA), Sulaiman Al Rajhi Colleges (SA), King Saud University (SA), Jazan University (SA)
Climate action
Openalex Percentile: Top 32%
Additive Manufacturing and 3D Printing Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.