Experimental investigation on accuracy of a Coriolis flowmeter in wide Reynolds number range by using various hydrocarbon liquids including LPG

OVAL Corporation, National Metrology Institute of Japan (NMIJ) and National Measurement Institute of Australia (NMIA) have jointly conducted a series of accuracy tests of a Coriolis flowmeter in wide Reynolds number range from 2600 to 660 000 by using various hydrocarbon liquids including LPG. The flow meter targeted for the test was a commercial type Coriolis flowmeter of 15 mm diameter with a typical gate-shaped structure, and was manufactured by OVAL Corporation. The result shows that once this type of Coriolis flowmeter is calibrated around Reynolds number 50 000 with hydrocarbon test liquids such as gasoline or kerosene, the calibration result is applicable to the measurement of LPG flow with Reynolds number at or above 50 000.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-28
DOI
https://doi.org/10.1016/j.measen.2024.101541
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on accuracy of a Coriolis flowmeter in wide Reynolds number range by using various hydrocarbon liquids including LPG

Simon Dignan, Ryouji DOIHARA, Yoshiya TERAO, Yuichi Nakao et al.
Measurement Sensors
Flow Measurement and Analysis
article

Experimental investigation on accuracy of a Coriolis flowmeter in wide Reynolds number range by using various hydrocarbon liquids including LPG

Simon Dignan, Ryouji DOIHARA, Yoshiya TERAO, Yuichi Nakao, K. Uchida, Ryotaro Agata
article en

Abstract

OVAL Corporation, National Metrology Institute of Japan (NMIJ) and National Measurement Institute of Australia (NMIA) have jointly conducted a series of accuracy tests of a Coriolis flowmeter in wide Reynolds number range from 2600 to 660 000 by using various hydrocarbon liquids including LPG. The flow meter targeted for the test was a commercial type Coriolis flowmeter of 15 mm diameter with a typical gate-shaped structure, and was manufactured by OVAL Corporation. The result shows that once this type of Coriolis flowmeter is calibrated around Reynolds number 50 000 with hydrocarbon test liquids such as gasoline or kerosene, the calibration result is applicable to the measurement of LPG flow with Reynolds number at or above 50 000.

Measurement SensorsVol. 38
National Measurement Institute (AU), National Institute of Advanced Industrial Science and Technology (JP), JGC (Japan) (JP)
Clean water and sanitation
Openalex Percentile: Top 73%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental investigation on accuracy of a Coriolis flowmeter in wide Reynolds number range by using various hydrocarbon liquids including LPG — Simon Dignan, Ryouji DOIHARA, et al. · Measurement Sensors (2024) | TGRS Research Map | TGRS