Customization of an efficient and cost-effective optical biosensor for trace cadmium detection in milk samples

Conventional techniques for detecting Cd, such as [e.g., atomic absorption spectrometry (AAS), inductively coupled plasma-mass spectrometry (ICP-MS)], often require expensive equipment, extensive sample preparation or specialized expertise. This novel research demonstrates how to customize an effective optical biosensor to detect low Cadmium (Cd) ion levels in milk samples. Compared to the previous report's detection limit of 8.1 μg/L, this unique approach shows a lower limit of 4.8 μg/L. Such fabricated optical biosensor was designed to monitor urease activity to detect Cd ions in milk samples, where calibration was performed using UV–Vis spectroscopy and further validation was done using ICP-MS technology. In this process, the urease enzyme was extracted from the jack bean, which was further immobilized using EDC-NHS coupling for the functionalization, thus optimizing stability and reactivity. An activity assay was performed for immobilized urease at pH 7.5; the optimized enzyme was 67 % stable for up to four weeks of storage at 4 °C due to excellent crosslinking during functionalization and immobilization. The coefficient of determination (R 2 ) was calculated to measure the proportion of biosensor readings with standard readings obtained by the ICP-MS readings. The proposed method obtained a moderate R 2 value close to 1, i.e., 0.88674, indicating a moderate agreement between ICMP readings and the proposed biosensor readings. Remarkably, the optical biosensor exhibits great stability and efficiency in detecting Cd ions in milk as low as 4.8 μg/L. FESEM and FTIR spectroscopy were used to examine the morphological and structural properties of the immobilized enzyme. The findings imply that the intended optical biosensor can be employed for on-field detection.

Authors

Institutions

Publication Details

Journal
Hybrid Advances
Published
2024-12-28
DOI
https://doi.org/10.1016/j.hybadv.2024.100367
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Customization of an efficient and cost-effective optical biosensor for trace cadmium detection in milk samples

Ajeet Kaushik, Arif D. Sheikh, Harish Mudila, Varsha S. Pawar et al.
3 citations
Hybrid Advances
Advanced Chemical Sensor Technologies
0.55
article

Customization of an efficient and cost-effective optical biosensor for trace cadmium detection in milk samples

Ajeet Kaushik, Arif D. Sheikh, Harish Mudila, Varsha S. Pawar, Anil Kumar, Shivaji D. Pawar
article en
3 citations

Abstract

Conventional techniques for detecting Cd, such as [e.g., atomic absorption spectrometry (AAS), inductively coupled plasma-mass spectrometry (ICP-MS)], often require expensive equipment, extensive sample preparation or specialized expertise. This novel research demonstrates how to customize an effective optical biosensor to detect low Cadmium (Cd) ion levels in milk samples. Compared to the previous report's detection limit of 8.1 μg/L, this unique approach shows a lower limit of 4.8 μg/L. Such fabricated optical biosensor was designed to monitor urease activity to detect Cd ions in milk samples, where calibration was performed using UV–Vis spectroscopy and further validation was done using ICP-MS technology. In this process, the urease enzyme was extracted from the jack bean, which was further immobilized using EDC-NHS coupling for the functionalization, thus optimizing stability and reactivity. An activity assay was performed for immobilized urease at pH 7.5; the optimized enzyme was 67 % stable for up to four weeks of storage at 4 °C due to excellent crosslinking during functionalization and immobilization. The coefficient of determination (R 2 ) was calculated to measure the proportion of biosensor readings with standard readings obtained by the ICP-MS readings. The proposed method obtained a moderate R 2 value close to 1, i.e., 0.88674, indicating a moderate agreement between ICMP readings and the proposed biosensor readings. Remarkably, the optical biosensor exhibits great stability and efficiency in detecting Cd ions in milk as low as 4.8 μg/L. FESEM and FTIR spectroscopy were used to examine the morphological and structural properties of the immobilized enzyme. The findings imply that the intended optical biosensor can be employed for on-field detection.

Hybrid AdvancesVol. 8
Lovely Professional University (IN), All India Council for Technical Education (IN), Universal Engineering College (IN), Florida Polytechnic University (US)
Affordable and clean energy
Openalex Percentile: Top 35%
Advanced Chemical Sensor Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.