Loss values of style transfer from UBM to AS-OCT images for plateau iris classification

Ultrasound biomicroscopy (UBM) is the standard for diagnosing plateau iris, but its limited accessibility in routine clinical settings presents challenges. While anterior segment optical coherence tomography (AS-OCT) is more convenient, its effectiveness in detecting plateau iris is limited. Previous research has demonstrated that combining UBM and AS-OCT image pairs through neural style transfer has improved classification accuracy. However, obtaining paired images is impractical in everyday practice. In this study, we propose a novel semi-supervised approach that eliminates the need for paired images. A generative model learns to distinguish plateau and non-plateau features from UBM images. AS-OCT images are input into the generator, which attempts to transform them into corresponding UBM images. The model's performance is measured by loss values, representing the difficulty of transforming AS-OCT images, which are then used to predict plateau iris. The classification baseline, which applies AS-OCT solely without the style-transfer of UBM information, obtained 52.72% sensitivity, 60.82% specificity, and 57.89% accuracy for external validation; in contrast, the classification with neural style transfer of the image pairs respectively obtained 94.54%, 100.00%, and 98.03%, whereas the semi-supervised approach using loss values classification obtained 93.10%, 93.13%, and 93.12%, respectively. This semi-supervised transfer learning model presents a novel technique for detecting plateau iris with AS-OCT.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-12-28
DOI
https://doi.org/10.1038/s41598-024-82327-5
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Loss values of style transfer from UBM to AS-OCT images for plateau iris classification

Pantid Chantangphol, Boonsong Wanichwecharungruang, Thanaruk Theeramunkong, Warisara Pattanapongpaiboon et al.
Scientific Reports
Optical Coherence Tomography Applications
article

Loss values of style transfer from UBM to AS-OCT images for plateau iris classification

Pantid Chantangphol, Boonsong Wanichwecharungruang, Thanaruk Theeramunkong, Warisara Pattanapongpaiboon, Natsuda Kaothanthong
article en

Abstract

Ultrasound biomicroscopy (UBM) is the standard for diagnosing plateau iris, but its limited accessibility in routine clinical settings presents challenges. While anterior segment optical coherence tomography (AS-OCT) is more convenient, its effectiveness in detecting plateau iris is limited. Previous research has demonstrated that combining UBM and AS-OCT image pairs through neural style transfer has improved classification accuracy. However, obtaining paired images is impractical in everyday practice. In this study, we propose a novel semi-supervised approach that eliminates the need for paired images. A generative model learns to distinguish plateau and non-plateau features from UBM images. AS-OCT images are input into the generator, which attempts to transform them into corresponding UBM images. The model's performance is measured by loss values, representing the difficulty of transforming AS-OCT images, which are then used to predict plateau iris. The classification baseline, which applies AS-OCT solely without the style-transfer of UBM information, obtained 52.72% sensitivity, 60.82% specificity, and 57.89% accuracy for external validation; in contrast, the classification with neural style transfer of the image pairs respectively obtained 94.54%, 100.00%, and 98.03%, whereas the semi-supervised approach using loss values classification obtained 93.10%, 93.13%, and 93.12%, respectively. This semi-supervised transfer learning model presents a novel technique for detecting plateau iris with AS-OCT.

Scientific ReportsVol. 14(1)
Thammasat University (TH), Priest Hospital (TH), Rajavithi Hospital (TH), Ministry of Science and Technology Thailand (TH), Rangsit University (TH)
Thailand Research Fund, Thammasat University
Climate action
Openalex Percentile: Top 77%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.