In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built. Capsulorhexes were modeled with a 4.5- and 5.5-mm diameter. The capsulorhexis was shifted 0.5-1 mm in two in-plane directions normal to the optical axis. Three IOLs with different powers (5 D, 29 D, and 34 D) were compared. The results were also compared with currently published numerical and clinical studies. With different capsulorhexes sizes and locations, the decentration varied from 0.43 to 8.3 μm, and the tilt varied 0.02° - 0.09°. The 34 D lens had the largest tilt and decentration when capsulorhexis changed sizes or decentered. The simulation showed that capsulorhexis size and decentration have only a minor effect on IOL decentration or tilt that will in most cases not be noticeable to the patient.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-12-28
DOI
https://doi.org/10.1038/s41598-024-82377-9
Citations
3
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of capsulorhexis size and position on post-surgical IOL alignment

Henk A Weeber, Carmen Cánovas Vidal, Shima Bahramizadeh Sajadi, Bram Koopman et al.
3 citations
Scientific Reports
Intraocular Surgery and Lenses
1.62
article

Effects of capsulorhexis size and position on post-surgical IOL alignment

Henk A Weeber, Carmen Cánovas Vidal, Shima Bahramizadeh Sajadi, Bram Koopman, J. Rozema, Liying Feng
article en
3 citations

Abstract

In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built. Capsulorhexes were modeled with a 4.5- and 5.5-mm diameter. The capsulorhexis was shifted 0.5-1 mm in two in-plane directions normal to the optical axis. Three IOLs with different powers (5 D, 29 D, and 34 D) were compared. The results were also compared with currently published numerical and clinical studies. With different capsulorhexes sizes and locations, the decentration varied from 0.43 to 8.3 μm, and the tilt varied 0.02° - 0.09°. The 34 D lens had the largest tilt and decentration when capsulorhexis changed sizes or decentered. The simulation showed that capsulorhexis size and decentration have only a minor effect on IOL decentration or tilt that will in most cases not be noticeable to the patient.

Scientific ReportsVol. 14(1)
University of Antwerp (BE), Antwerp University Hospital (BE), Johnson & Johnson (Israel) (IL), Johnson & Johnson (Netherlands) (NL)
European Commission
Openalex Percentile: Top 15%
Intraocular Surgery and Lenses
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.