Towards the monitoring of dialysis treatment through absorption and endogenous fluorescence techniques

This study explores the monitoring of uraemic toxins in haemodialysis treatments, beyond urea concentration, in the perspective of reducing complications stemming from the lack of personalized haemodialysis therapies. Absorption and fluorescence techniques were employed to analyse low-middle weight molecules employing laboratory prepared solutions combining p-cresol, bovine albumin and bisphenol-A molecules. These optical techniques offer the advantage of analysing the sample without physical contact, ensuring the potential for implementation in a real-world scenario for continuous treatment monitoring. Real-time monitoring of these toxins in spent dialysate could offer insights into blood concentrations, enhancing dialysis treatment optimization and complication management. The considered absorption spectra fell within the ultraviolet range (240, 400) nm, while fluorescence spectra were obtained at a selected excitation wavelength of 285 nm. Data analysis revealed a correlation between molecule concentrations and signal intensity in both absorption and fluorescence measurements.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-26
DOI
https://doi.org/10.1016/j.measen.2024.101331
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards the monitoring of dialysis treatment through absorption and endogenous fluorescence techniques

Valentina Di Pinto, Alberto Ferrari, Giulia Ligabue, Giovanni Gibertoni et al.
Measurement Sensors
Dialysis and Renal Disease Management
article

Towards the monitoring of dialysis treatment through absorption and endogenous fluorescence techniques

Valentina Di Pinto, Alberto Ferrari, Giulia Ligabue, Giovanni Gibertoni, Marco Ferrarini, G. Galli, Luigi Rovati, Silvia Giovanella, Niccolò Morisi, Gabriele Donati
article en

Abstract

This study explores the monitoring of uraemic toxins in haemodialysis treatments, beyond urea concentration, in the perspective of reducing complications stemming from the lack of personalized haemodialysis therapies. Absorption and fluorescence techniques were employed to analyse low-middle weight molecules employing laboratory prepared solutions combining p-cresol, bovine albumin and bisphenol-A molecules. These optical techniques offer the advantage of analysing the sample without physical contact, ensuring the potential for implementation in a real-world scenario for continuous treatment monitoring. Real-time monitoring of these toxins in spent dialysate could offer insights into blood concentrations, enhancing dialysis treatment optimization and complication management. The considered absorption spectra fell within the ultraviolet range (240, 400) nm, while fluorescence spectra were obtained at a selected excitation wavelength of 285 nm. Data analysis revealed a correlation between molecule concentrations and signal intensity in both absorption and fluorescence measurements.

Measurement SensorsVol. 38
University of Modena and Reggio Emilia (IT)
European Commission, Ministero dell’Istruzione, dell’Università e della Ricerca
Openalex Percentile: Top 66%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards the monitoring of dialysis treatment through absorption and endogenous fluorescence techniques — Valentina Di Pinto, Alberto Ferrari, et al. · Measurement Sensors (2024) | TGRS Research Map | TGRS