Determination of Fluoroquinolones Antibiotics in Water by Polyrutin Film‐Modified Electrochemical Sensor

This study is aimed at the determination of a new pollutant, fluoroquinolones antibiotics (FQs). Taking ciprofloxacin (CIP) as the research representative, rutin polymer film‐modified sensor polyrutin modified glass carbon electrode (PRT/GCE) was prepared by electropolymerization, and a new analytical method for the determination of FQs was established, which is environmentally friendly, simple, efficient, and economical. The topography, elemental composition, and electrochemical behavior of the sensor were investigated using scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The results showed that the linear range of the PRT/GCE sensor used for CIP was 0.8–50 μM, the detection limit was 0.050 μM, and the recovery rate was 94.9%–104%. In addition, when it was used to detect norfloxacin (NOR), enrofloxacin (ENR), pefloxacin (PEF), and rofloxacin (FLE) in FQs, the sensor similarly exhibited a broad linear range; its corresponding detection limits were 0.078, 0.16, 0.088, and 0.12 μM, respectively. The PRT/GCE sensor had a high active area, good catalytic performance for FQs, simple preparation, stable performance, and reusability. It has potential application value for routine determination of fluoroquinolones in real water.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-12-26
DOI
https://doi.org/10.1002/elan.202400371
Citations
2
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Fluoroquinolones Antibiotics in Water by Polyrutin Film‐Modified Electrochemical Sensor

Wanglei Gou, Jiajian Gao, Jiao Qiu, Wen Chen
2 citations
Electroanalysis
Antibiotics Pharmacokinetics and Efficacy
0.90
article

Determination of Fluoroquinolones Antibiotics in Water by Polyrutin Film‐Modified Electrochemical Sensor

Wanglei Gou, Jiajian Gao, Jiao Qiu, Wen Chen
article en
2 citations

Abstract

This study is aimed at the determination of a new pollutant, fluoroquinolones antibiotics (FQs). Taking ciprofloxacin (CIP) as the research representative, rutin polymer film‐modified sensor polyrutin modified glass carbon electrode (PRT/GCE) was prepared by electropolymerization, and a new analytical method for the determination of FQs was established, which is environmentally friendly, simple, efficient, and economical. The topography, elemental composition, and electrochemical behavior of the sensor were investigated using scanning electron microscopy (SEM), X‐ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The results showed that the linear range of the PRT/GCE sensor used for CIP was 0.8–50 μM, the detection limit was 0.050 μM, and the recovery rate was 94.9%–104%. In addition, when it was used to detect norfloxacin (NOR), enrofloxacin (ENR), pefloxacin (PEF), and rofloxacin (FLE) in FQs, the sensor similarly exhibited a broad linear range; its corresponding detection limits were 0.078, 0.16, 0.088, and 0.12 μM, respectively. The PRT/GCE sensor had a high active area, good catalytic performance for FQs, simple preparation, stable performance, and reusability. It has potential application value for routine determination of fluoroquinolones in real water.

Electroanalysis
Chengdu University of Technology (CN)
Openalex Percentile: Top 22%
Antibiotics Pharmacokinetics and Efficacy
0.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.