3D printed microfluidic devices produced by material extrusion: effect of ironing parameters on mixing efficiency and gradient generation

Purpose This study aims to describe the effect of ironing process parameters on mixing efficiency and gradient generation in Y-micromixers and microfluidic gradient generators (MGGs), respectively. Design/methodology/approach Material extrusion (MEX) enables the production of miniaturized devices with the advantage of lower manufacturing costs and higher design freedom. However, surface finishing is the most important drawback when it comes to microfluidic applications where flow splitting is not required. First, the effect of ironing line spacing (LS) and speed (IS) on mixing efficiency in Y-micromixers was experimentally investigated. Then, the best ironing settings were chosen to further study the spatial stability of the normalized concentration gradient in MGGs. Findings Lower ironing LS and IS enhance the microchannel surface smoothness. The best combination of ironing parameters (lowest values of LS and IS) leads to an increase in mixing length of 191% at Q = 10 µL/min and 198% at Q = 20 µL/min, with respect to a similar Y-micromixer geometry where ironing was not performed. These findings were applied in the production of a MGG, showing that the normalized concentration gradient in the crosswise flow direction does not depend on the streamwise position when ironing is performed. Originality/value To the best of the authors’ knowledge, for the first time, the possibility of optimizing ironing parameters to enhance the surface roughness in MEX microfluidic devices has been investigated. Ironing of the channel bottom surface allows to reduce ridges-induced flow convection, thus delaying mixing in Y-micromixers and achieving stable concentration gradient in MGGs.

Authors

Institutions

Publication Details

Journal
Rapid Prototyping Journal
Published
2024-12-27
DOI
https://doi.org/10.1108/rpj-06-2024-0236
Citations
2
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D printed microfluidic devices produced by material extrusion: effect of ironing parameters on mixing efficiency and gradient generation

Gianluca Percoco, Alessio Pricci
2 citations
Rapid Prototyping Journal
Microfluidic and Capillary Electrophoresis Applications
0.37
article

3D printed microfluidic devices produced by material extrusion: effect of ironing parameters on mixing efficiency and gradient generation

Gianluca Percoco, Alessio Pricci
article en
2 citations

Abstract

Purpose This study aims to describe the effect of ironing process parameters on mixing efficiency and gradient generation in Y-micromixers and microfluidic gradient generators (MGGs), respectively. Design/methodology/approach Material extrusion (MEX) enables the production of miniaturized devices with the advantage of lower manufacturing costs and higher design freedom. However, surface finishing is the most important drawback when it comes to microfluidic applications where flow splitting is not required. First, the effect of ironing line spacing (LS) and speed (IS) on mixing efficiency in Y-micromixers was experimentally investigated. Then, the best ironing settings were chosen to further study the spatial stability of the normalized concentration gradient in MGGs. Findings Lower ironing LS and IS enhance the microchannel surface smoothness. The best combination of ironing parameters (lowest values of LS and IS) leads to an increase in mixing length of 191% at Q = 10 µL/min and 198% at Q = 20 µL/min, with respect to a similar Y-micromixer geometry where ironing was not performed. These findings were applied in the production of a MGG, showing that the normalized concentration gradient in the crosswise flow direction does not depend on the streamwise position when ironing is performed. Originality/value To the best of the authors’ knowledge, for the first time, the possibility of optimizing ironing parameters to enhance the surface roughness in MEX microfluidic devices has been investigated. Ironing of the channel bottom surface allows to reduce ridges-induced flow convection, thus delaying mixing in Y-micromixers and achieving stable concentration gradient in MGGs.

Rapid Prototyping JournalVol. 31(4)
Polytechnic University of Bari (IT)
Openalex Percentile: Top 41%
Microfluidic and Capillary Electrophoresis Applications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

3D printed microfluidic devices produced by material extrusion: effect of ironing parameters on mixing efficiency and gradient generation — Gianluca Percoco, Alessio Pricci · Rapid Prototyping Journal (2024) | TGRS Research Map | TGRS