Exploring Near- and Far-Field Effects in Photoplethysmography Signals Across Different Source–Detector Distances

Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source-detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance. The coefficient of variation (CV) is proposed as a new signal quality index (SQI) to evaluate signal variabilities. This study first characterizes the PPG system, which is then used to acquire PPG signals in the chest of 14 healthy participants. Results show a great DC variability at 6 mm, homogenizing at 9 and 12 mm. This suggests that PPG systems are also sensitive to the near- and far-field effects commonly reported and studied in optics, which can impact the accuracy of physiological parameters dependent on the DC component, such as oxygen saturation (SpO<sub>2</sub>).

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-27
DOI
https://doi.org/10.3390/s25010099
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Near- and Far-Field Effects in Photoplethysmography Signals Across Different Source–Detector Distances

Kevin De Pauw, Johan Stiens, Joan Lambert Cause, Ángel Solé Morillo et al.
2 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.37
article

Exploring Near- and Far-Field Effects in Photoplethysmography Signals Across Different Source–Detector Distances

Kevin De Pauw, Johan Stiens, Joan Lambert Cause, Ángel Solé Morillo, Bruno da Silva
article en
2 citations

Abstract

Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source-detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance. The coefficient of variation (CV) is proposed as a new signal quality index (SQI) to evaluate signal variabilities. This study first characterizes the PPG system, which is then used to acquire PPG signals in the chest of 14 healthy participants. Results show a great DC variability at 6 mm, homogenizing at 9 and 12 mm. This suggests that PPG systems are also sensitive to the near- and far-field effects commonly reported and studied in optics, which can impact the accuracy of physiological parameters dependent on the DC component, such as oxygen saturation (SpO<sub>2</sub>).

SensorsVol. 25(1)
Vrije Universiteit Brussel (BE), Universidad de Oriente (CU)
Fonds Wetenschappelijk Onderzoek, Vlaamse regering
Openalex Percentile: Top 41%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.