An Error Amplifier With Enhanced Slew Rate and Clamp Function Supporting Multi-Mode Control of Four-Switch-Buck-Boost Converter

This paper proposes a MOSFET-only error amplifier(EA) with clamp function, which reduces the power consumption to $71.7 \mu \mathrm{~A}$. Moreover, the circuit realizes the function of dynamic slewing rate enhancement, which can improve the performance of transient response. The static power consumption of the dynamic slewing rate enhancement module is only $4.7 \mu \mathrm{~A}$, and the slew rate ($\mathrm{SR}+\mid \mathrm{SR}-$) is $47.6 \mathrm{~V} / \boldsymbol{\mu s} \mid \mathbf{5 0. 2} \mathrm{V} / \boldsymbol{\mu s}$ when driving a $200-\mathrm{pF}$ load. The proposed error amplifier is designed with a 0.18 $\mu \mathrm{m}$ BCD process, demonstrating the capability to support the Four-Switch-Buck-Boost DC-DC power management circuit operating with multi-mode control.

Authors

Institutions

Publication Details

Published
2024-11-07
DOI
https://doi.org/10.1109/apccas62602.2024.10809017
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Error Amplifier With Enhanced Slew Rate and Clamp Function Supporting Multi-Mode Control of Four-Switch-Buck-Boost Converter

Zhongyuan Fang, Wenhui Fan, Jiahao Liu, Haonan Fan et al.
Advanced DC-DC Converters
article

An Error Amplifier With Enhanced Slew Rate and Clamp Function Supporting Multi-Mode Control of Four-Switch-Buck-Boost Converter

Zhongyuan Fang, Wenhui Fan, Jiahao Liu, Haonan Fan, Weifeng Sun
article en

Abstract

This paper proposes a MOSFET-only error amplifier(EA) with clamp function, which reduces the power consumption to $71.7 \mu \mathrm{~A}$. Moreover, the circuit realizes the function of dynamic slewing rate enhancement, which can improve the performance of transient response. The static power consumption of the dynamic slewing rate enhancement module is only $4.7 \mu \mathrm{~A}$, and the slew rate ($\mathrm{SR}+\mid \mathrm{SR}-$) is $47.6 \mathrm{~V} / \boldsymbol{\mu s} \mid \mathbf{5 0. 2} \mathrm{V} / \boldsymbol{\mu s}$ when driving a $200-\mathrm{pF}$ load. The proposed error amplifier is designed with a 0.18 $\mu \mathrm{m}$ BCD process, demonstrating the capability to support the Four-Switch-Buck-Boost DC-DC power management circuit operating with multi-mode control.

Southeast University (CN)
Nature
Affordable and clean energy
Openalex Percentile: Top 78%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.