An AOT-COT Dual-Mode Three-Level Buck Converter With Wide Load and Input Ranges

This paper presents a dual operation mode wide input-range three-level buck dc-dc converter. The converter can operate in either continuous-conduction mode (CCM) with a constant-frequency adaptive-on-time ($\mathrm{CF}-\mathrm{AOT}$) control or in discontinuous-conduction mode (DCM) with a constant-on-time (COT) control, depending on the load condition in order to achieve high power conversion efficiency over a wide load range. A clock-free scheme is proposed to generate a duty signal with a 180° phase shift without using a clock, thereby enabling the converter to achieve a fast load response when a load current step occurs. A DCM zero-voltage-switching (ZVS) control scheme for the low-side power transistors during off-time is also developed to remove the switching power loss due to V-I overlap, thereby improving the efficiency in light load condition. Simulated in a 180 nm BCD process, the proposed converter regulates the output voltage at 1 V and achieves a maximum power efficiency of 89.6% in CCM and 85% in DCM. Besides, the proposed converter shows a fast load transient response with a $29-\mathrm{mV}$ output voltage droop for a 2 A current step with 10-ns rising time.

Authors

Institutions

Publication Details

Published
2024-11-07
DOI
https://doi.org/10.1109/apccas62602.2024.10808743
Citations
3
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An AOT-COT Dual-Mode Three-Level Buck Converter With Wide Load and Input Ranges

Yan Lü, Zhiming He
3 citations
Advanced DC-DC Converters
0.63
article

An AOT-COT Dual-Mode Three-Level Buck Converter With Wide Load and Input Ranges

Yan Lü, Zhiming He
article en
3 citations

Abstract

This paper presents a dual operation mode wide input-range three-level buck dc-dc converter. The converter can operate in either continuous-conduction mode (CCM) with a constant-frequency adaptive-on-time ($\mathrm{CF}-\mathrm{AOT}$) control or in discontinuous-conduction mode (DCM) with a constant-on-time (COT) control, depending on the load condition in order to achieve high power conversion efficiency over a wide load range. A clock-free scheme is proposed to generate a duty signal with a 180° phase shift without using a clock, thereby enabling the converter to achieve a fast load response when a load current step occurs. A DCM zero-voltage-switching (ZVS) control scheme for the low-side power transistors during off-time is also developed to remove the switching power loss due to V-I overlap, thereby improving the efficiency in light load condition. Simulated in a 180 nm BCD process, the proposed converter regulates the output voltage at 1 V and achieves a maximum power efficiency of 89.6% in CCM and 85% in DCM. Besides, the proposed converter shows a fast load transient response with a $29-\mathrm{mV}$ output voltage droop for a 2 A current step with 10-ns rising time.

University of Macau (MO), Institute of Microelectronics (CN)
National Natural Science Foundation of China, Technology Development
Affordable and clean energy
Openalex Percentile: Top 30%
Advanced DC-DC Converters
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An AOT-COT Dual-Mode Three-Level Buck Converter With Wide Load and Input Ranges — Yan Lü, Zhiming He · (2024) | TGRS Research Map | TGRS