Design of Volumetric Magnetic Induction Tomography (VMIT) System Using COMSOL Simulation

Magnetic Induction Tomography (MIT) is a low-resolution imaging technique used to reconstruct the magnetic permeability distribution of an object. COMSOL Simulation of VMIT (Volumetric Magnetic Induction Tomography) system has been developed by using 8 coils as transmitter and 8 coils as receiver. The existence of sine excitation signal in the transmitter coil cause magnetic field changing, it causing emf at the receiver coil. The magnitude of the magnetic field induction is also influenced by the permeability of the medium between the transmitter and receiver coils. COMSOL and MATLAB simulation of VMIT 8 coil systems indicate that, by using ILBP algorithms, ball-shaped object with ferromagnetic materials (iron) can be reconstructed to produce a similar image. The sensitivity matrix significantly influences image reconstruction in MIT, leading to distorted elliptical images of objects, particularly when positioned at the top center, as the matrix shows homogeneity mainly in the middle area.

Authors

Institutions

Publication Details

Published
2024-11-12
DOI
https://doi.org/10.1109/icramet62801.2024.10809219
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Volumetric Magnetic Induction Tomography (VMIT) System Using COMSOL Simulation

Prawito Prajitno, Warsito Purwo Taruno, Muhammad Nurul Puji
2 links
Electrical and Bioimpedance Tomography
article

Design of Volumetric Magnetic Induction Tomography (VMIT) System Using COMSOL Simulation

Prawito Prajitno, Warsito Purwo Taruno, Muhammad Nurul Puji
article en

Abstract

Magnetic Induction Tomography (MIT) is a low-resolution imaging technique used to reconstruct the magnetic permeability distribution of an object. COMSOL Simulation of VMIT (Volumetric Magnetic Induction Tomography) system has been developed by using 8 coils as transmitter and 8 coils as receiver. The existence of sine excitation signal in the transmitter coil cause magnetic field changing, it causing emf at the receiver coil. The magnitude of the magnetic field induction is also influenced by the permeability of the medium between the transmitter and receiver coils. COMSOL and MATLAB simulation of VMIT 8 coil systems indicate that, by using ILBP algorithms, ball-shaped object with ferromagnetic materials (iron) can be reconstructed to produce a similar image. The sensitivity matrix significantly influences image reconstruction in MIT, leading to distorted elliptical images of objects, particularly when positioned at the top center, as the matrix shows homogeneity mainly in the middle area.

Binus University (ID), University of Indonesia (ID)
Affordable and clean energy
Openalex Percentile: Top 78%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of Volumetric Magnetic Induction Tomography (VMIT) System Using COMSOL Simulation — Prawito Prajitno, Warsito Purwo Taruno, et al. · (2024) | TGRS Research Map | TGRS