Oscillation Control in Aceh System Under Disturbances: A Case Study

This study examines the dynamic response of the Aceh power system under disturbances, focusing on oscillation control. The primary concern is the critical damping of generator rotor angle modes, which can either be oscillatory or fully damped. Damping reduction is problematic as it prolongs oscillations, adversely affecting system stability. The eigenvalues and participating modes during disturbances are analyzed to determine the optimal strategy for enhancing system stability. Various operational scenarios and Power System Stabilizer (PSS) tuning methods are evaluated through dynamic simulations. The results demonstrate that tuning PSSs on all units at the Nagan Raya power plant yields the most effective improvement in system response, reducing oscillation duration and enhancing overall stability.

Authors

Institutions

Publication Details

Published
2024-10-23
DOI
https://doi.org/10.1109/icitee62483.2024.10808794
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oscillation Control in Aceh System Under Disturbances: A Case Study

Husni Rois Ali, Fuad Husain Akbar, Lesnanto Multa Putranto
Frequency Control in Power Systems
article

Oscillation Control in Aceh System Under Disturbances: A Case Study

Husni Rois Ali, Fuad Husain Akbar, Lesnanto Multa Putranto
article en

Abstract

This study examines the dynamic response of the Aceh power system under disturbances, focusing on oscillation control. The primary concern is the critical damping of generator rotor angle modes, which can either be oscillatory or fully damped. Damping reduction is problematic as it prolongs oscillations, adversely affecting system stability. The eigenvalues and participating modes during disturbances are analyzed to determine the optimal strategy for enhancing system stability. Various operational scenarios and Power System Stabilizer (PSS) tuning methods are evaluated through dynamic simulations. The results demonstrate that tuning PSSs on all units at the Nagan Raya power plant yields the most effective improvement in system response, reducing oscillation duration and enhancing overall stability.

Universitas Gadjah Mada (ID)
Universitas Gadjah Mada
Openalex Percentile: Top 78%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Oscillation Control in Aceh System Under Disturbances: A Case Study — Husni Rois Ali, Fuad Husain Akbar, et al. · (2024) | TGRS Research Map | TGRS