Analysis of Power Supply Parameters for Indirect Process Control

Most processes in chemical technologies are performed on non-transparent equipment (metal, opaque plastic, thermally insulated equipment). This prevents visual monitoring of the process in progress and, in certain cases, necessitates the installation of costly and sophisticated optical sensors in the machinery in order to enable the automation governing the process to make the required decisions. At the same time, most of these changes can be detected by indirect signs using sensors already installed in the system, which makes it possible to simplify and reduce the cost of parameter monitoring methods. One of these methods can be the use of data received from a monitor of electrical network parameters. In some cases, changes in the value of consumed currents, active and apparent power can be clearly associated with the processes occurring in the “black box”, and after proper calibration, serve as reliable criteria for making certain decisions.

Authors

Institutions

Publication Details

Published
2024-09-20
DOI
https://doi.org/10.1109/icmra62519.2024.10809230
Citations
1
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Power Supply Parameters for Indirect Process Control

Andrey B. Ilyin, Sohyla M. Aboudeif
1 citations
Engineering Diagnostics and Reliability
0.27
article

Analysis of Power Supply Parameters for Indirect Process Control

Andrey B. Ilyin, Sohyla M. Aboudeif
article en
1 citations

Abstract

Most processes in chemical technologies are performed on non-transparent equipment (metal, opaque plastic, thermally insulated equipment). This prevents visual monitoring of the process in progress and, in certain cases, necessitates the installation of costly and sophisticated optical sensors in the machinery in order to enable the automation governing the process to make the required decisions. At the same time, most of these changes can be detected by indirect signs using sensors already installed in the system, which makes it possible to simplify and reduce the cost of parameter monitoring methods. One of these methods can be the use of data received from a monitor of electrical network parameters. In some cases, changes in the value of consumed currents, active and apparent power can be clearly associated with the processes occurring in the “black box”, and after proper calibration, serve as reliable criteria for making certain decisions.

Moscow Institute of Physics and Technology (RU)
Affordable and clean energy
Openalex Percentile: Top 46%
Engineering Diagnostics and Reliability
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Power Supply Parameters for Indirect Process Control — Andrey B. Ilyin, Sohyla M. Aboudeif · (2024) | TGRS Research Map | TGRS